Geosense HLC 6000 Series Скачать руководство пользователя страница 16

16

 

V1.0 July 2020

 

6.3.1 

 

Data Reduction overview contd...

 

 

An instrument calibration sheet similar to the example in the Section 6.6 of this manual in-

cludes the following information:

 

 
 

Model 

 

 

 

This refers to the Geosense model number.

 

 

Serial Number

   

This is a unique sensor identification number that can be found 

  

   

 

 

 

on the load cell body and, for long cables, at the end of the cable.

 

 

Works ID

   

 

Unique works batch and range code

 

 

Cal Date

   

 

Date the calibration was performed

 

 

Baro

  

 

 

Barometric Pressure at the time of calibration

 

 

Temp 

o

C

   

 

Temperature at which the load cell was calibrated

 

 

Applied Pressure

 

Pressure applied to the transducer as part of the calibration 

 

 

   

 

 

 

cycle 

 

 

Readings [digit]

  

Readings from the transducer as pressure is applied and as 

 

 

   

 

 

 

pressure is reduced, in steps. The average is calculated.

 

 

Calculated Pressure

 

Calculation of the applied pressure using the calculated 

   

 

   

 

 

 

3rd order Polynomial for comparison with the actual Applied 

 

 

   

 

 

 

Pressure.

 

 

Error % FSO

 

 

Non Linearity expressed as a percentage of the transducers 

 

 

   

 

 

 

Full Scale.

 

 

Calibration Factors

 

‘‘

Polynomial

’ 

factors are provided for conversion to kN

 

 

An example of the calculation from Linear Digits ( Hz

2

/1000) to kN using a polynomial equa-

tion is given below:

  
             

 Calibration Factors for kN 

 

 

A

       

-

 5.14962E

-

10

 

B

       

=

  

 1.1669E

-

5

 

C

      

 = 

-

 0.333375086

 

D

      

 = 

  

2599.399697

             

 

 

             

 

 

             

 Current Reading in Linear Digits

  

 = 8475

 

  
   

 Equation 

 

  
             

 Load in kN = [ A x ( Reading )

3

 ] + [ B x ( Reading )

2

 ] + [ C x Reading ] 

 

+ D

 

                                           

 

 

=

 

 [

-

 5.14962E

-

10

 x (8475)

3

] + [1.1669E

-

5 x (8475)

2

] + [

-

 0.333375086 x 8475] + 2599.399697

 

 

-

313. 838. 

-

2825. 2599.399697

 

                            

 

                                          

 

 

= 298.710 kN

 

   

 

 

 
 

Содержание HLC 6000 Series

Страница 1: ...V1 0 July 2020 I N S T R U C T I O N M A N U A L HLC 6000 SERIES HYDRAULIC ANCHOR LOAD CELLS...

Страница 2: ...2 V1 0 July 2020...

Страница 3: ...7 4 4 Storage 7 5 0 INSTALLATION 5 1 General issues 8 5 2 General considerations 8 5 3 Mounting surfaces 8 5 4 Installation 10 6 0 DATA HANDLING 13 6 1 Monitoring the load cell readings 13 6 2 Portabl...

Страница 4: ...the cell the pressure of the inside liquid changes The changes in pressure correspond directly to the load applied Manufactured with a centre hole to accommodate anchors rock bolts and tendons The pre...

Страница 5: ...se of certain Hazardous Substances RoHS2 2017 2102 EU Waste electrical electronic equipment WEEE 2012 19 EU Equipment description Hydraulic load cells Make brand Geosense Model numbers HLC 6000 HLC 65...

Страница 6: ...eosense HLC 6000 Series Hydraulic Anchor Load Cells are labelled with the following information Manufacturers name address Product Type Model Range Serial number CE mark WEEE mark HLC 6000 with Manome...

Страница 7: ...obust to allow normal handling by transportation companies Inappropriate handling techniques may cause damage to the packaging and the enclosed equipment The packaging should be carefully inspected up...

Страница 8: ...th the factory zero on the calibration sheet see the example calibration sheet in Section 9 within 50 digits after barometric and temperature corrections are made The elevation of the Geosense factory...

Страница 9: ...ng system and mark cables at frequent intervals not just at the ends Protect the ends of the signal cable Cables should be terminated at a waterproof box or with waterproof connectors 5 2 General cons...

Страница 10: ...y The applied load must be perpendicular centered and uniform over the Load Cell surface Avoid load concentrations Make sure loading surfaces are accurately levelled and parallel If necessary fabricat...

Страница 11: ...plate STEP 2 Lower the Load Cell over the tensioning member s and onto the loading surface abutment plate TAKE A ZERO LOAD READING SEE DATA HANDLING FOR VW STEP 3 Lower the Distribution Plate over th...

Страница 12: ...4 Place the Wedge Plate over the tensioning member s and onto the load distribution plate and additional top load plate optional STEP 5 Slowly lower the tensioning jack over the tensioning member s 5...

Страница 13: ...tribution plate or top load plate where applicable STEP 7 Tension the strands as required and take readings from the VW transducer or manometer as necessary TAKE CARE NOT TO OVER RANGE THE LOAD CELL I...

Страница 14: ...a brief step by step procedure for use with the Geosense VWR 1 portable readout 1 Connect signal cable from the sensor to the readout following the wiring colour code Conductor colours may vary depen...

Страница 15: ...upplied with every Geosense Vibrating Wire Transducer If the readout displays Frequency values e g 2768 5 Hz only a simple calculation is re quired to convert the readings to Linear Digits Linear Digi...

Страница 16: ...cle Readings digit Readings from the transducer as pressure is applied and as pressure is reduced in steps The average is calculated Calculated Pressure Calculation of the applied pressure using the c...

Страница 17: ...17 V1 0 July 2020 6 5 CALIBRATION Vibrating Wire...

Страница 18: ...18 V1 0 July 2020 6 5 CALIBRATION contd Pressure gauge Manometer...

Страница 19: ...it is necessary to first establish the effects of the temperature changes on the load cell and the medium in on which it is installed A useful exercise to carry out on site to establish the in situ ef...

Страница 20: ...the system that cause elasticity in the system it is the release of the stored energy in the system whilst transferring load to the anchor and so at the same time through the load cell that cause this...

Страница 21: ...ilable ii Make sure that suitably thick distribution plates are being used so that load will be distributed to the load cell as a UDL Uniformly distributed load VW Load cell is giving unstable reading...

Страница 22: ...nly on very rare occasions will this be untrue In almost all cases a fluctuating reading is a sign of a faulty signal from the sensor The fault could be in either the sensor the connecting cable any s...

Страница 23: ...gh tensile stress relieved steel Output signal Manual Frequency Capacity kN Internal diameter mm Outside Diameter mm Load Cell Height mm Load distribution plate height mm 250 40 140 30 30 500 71 170 3...

Страница 24: ...s defects which arise as a result of a failure in design or manufacturing It is a condition of the warranty that the Geosense Geosense HLC 6000 Series load cells must be installed and used in accordan...

Страница 25: ...all be at the expense of the Purchaser Return shipment of repaired replaced part or parts covered by this warranty shall be at the expense of the Manufacturer Unauthorised alteration and or repair by...

Страница 26: ...26 V1 0 July 2020 VIBRATING WIRE ANCHOR LOAD CELLS HLC 6000 SERIES...