S53-053 Panther
18 of 53
To fill the oil tank
:
Step Action
Information
Remark(s)
Fig.
Switch/item
1.
Make sure all cylinders are completely
retracted
-
-
2.
Check if the engine is not running
Refer to chapter
9
-
-
3.
- Open the upper welding socket on the
side of the tank
- square fill hatch on top of the power
pack housing
Remove the plug
Remove the bolts
-
-
4.
When filling through the welding
socket open the tank breather filter
Turn counter
clockwise
-
-
5.
Fill the oil tank with oil
Use only
recommended
oils!
5 A
-
Fill the tank until the oil level reaches
the top blue line of the oil level gauge
Do not overfill
the oil tank!
6.
Replace the tank breather filter
-
-
7.
Close the oil tank
-
-
7.1.3
Hydraulic oil temperature
The limits regarding oil temperature depend on the hydraulic oil type; the standard setting is oil type VG46, of
which the operating temperatures are displayed below.
If another oil type is used, please contact Geomil Equipment BV to change the oil temperature settings.
Oil temperature
= normal
No warnings; normal operation; ( < 65 degrees Celsius )
Oil temperature
= hot
Warning; operator intervention needed; ( 65-75 degrees Celsius )
Oil temperature
= critical
Warning; shutdown the system to protect vehicle; ( > 75 degrees
Celsius )
CPT
For warnings during CPT testing refer to the CPTest manual
Engine
Engine warnings are displayed on the Deepsea control panel. For engine warnings refer to the Deepsea/JCB
manual.