11
Troubleshooting
Alert
Symptom
Possible causes and solu-
tions
007746_001
Low Battery indication on the
display.
The batteries are low.
Recharge the Li-Ion battery
pack. Refer to "9 Batteries".
007610_001
Elevation (H.I.) Alert The Elev-
ation (H.I.) Alert screen is
shown and the audio beeps.
(Level position)
The Zone60 DG has been
bumped or tripod was moved.
Turn off Zone60 DG to stop
alert, check the height of the
laser before beginning to work
again. Allow Zone60 DG to
relevel and check the height of
the laser. After 2 minutes in
the alert condition, the unit will
shut off automatically.
007747_001
Servo Limit Alert
The Servo Limit Alert screen is
shown.
The Zone60 DG is tipped too
far to reach a level position.
Relevel the Zone60 DG within
the 6 degree self-levelling
range. After 2 minutes in the
alert condition, the unit will
shut off automatically.
007748_001
Tilt Alert
The Tilt Alert screen is shown.
The Zone60 DG is tipped more
than 45° from level. After
2 minutes in the alert condi-
tion, the unit will shut off auto-
matically.
007749_001
Temperature Alert
The Temperature Alert screen
is shown.
The Zone60 DG is in an envir-
onment where it cannot oper-
ate without damaging the laser
diode, for example being
exposed to the heat from dir-
ect sunlight. Shade the Zone60
DG from the sun. After
2 minutes in the alert condi-
tion, the unit will shut off auto-
matically.
007627_001
Temperature Check
The Temperature Check Alert
screen is shown.
The Zone60 DG has detected a
change in temperature of 5°C
and is checking the level posi-
tion.
☞
Wait until proced-
ure is complete.
ging the setting
between 5°C and
2°C.
Alerts and message
Screens
58
Troubleshooting