Problem
Possible Causes
Suggested Solutions
The distance of the laser
is reduced.
Dirt is reducing the laser
output.
Clean the windows of the Zone60
DG and the receiver. If the problem
continues, return the Zone60 DG to
an authorised service centre for
service.
The laser receiver is not
working properly.
The Zone60 DG is not
rotating. It may be level-
ling or in H.I.Alert.
Check for proper operation of the
Zone60 DG.
☞
Refer to the receiver
manual for more
information.
The receiver is out of
usable range.
Move closer to the Zone60 DG.
The batteries of the
receiver are low.
Check the low battery symbol on
the receiver display. Change the
receiver batteries.
The ZRC60 remote control
is not working properly.
The remote control is out
of usable range.
For normal operation, the remote
control works up to 300 m (1,000’).
The batteries of the
remote are low.
Check the Remote Battery LED on
the control panel. Change the
remote control batteries.
The display is too dark or
too light.
The setting of the display
brightness is unsuitable.
The brightness for both the Zone60
DG and the remote control can be
reset in the menu of the respective
device. Refer to " Display bright-
ness"(Zone60 DG) or to " Display
brightness"(Remote control).
The grade is shown in
percent(%) or per mil
(‰).
The wrong setting has
been selected.
Choose the desired setting in the
option menu. (" Display - percent/
The grade resets to zero
each time the laser is
turned on.
The wrong setting has
been selected.
Choose the desired setting in the
option menu. (" Show grade set-
The laser stops too often
to relevel.
The sensitivity setting
may be set to the “fine”
setting (Setting 1).
Choose the Sensitivity Setting 2 in
the option menu. (" Sensitivity set-
The Tripod may be
unstable.
Check your tripod for stability.
Tighten all screws. Use sand bags
on the legs if necessary.
The wind is causing the
Zone60 DG to move too
much.
Shelter the Zone60 DG from the
wind. Press the tripod legs more
firmly into the ground.
60
Troubleshooting