Zone20 H
| 24
Troubleshooting
8
Troubleshooting
Alerts
Troubleshooting
Alert
Symptom
Possible causes and solutions
Low Battery LED flashes red, or is on but
not flashing.
The batteries are low. Replace the
alkaline batteries or recharge the Li-
Ion battery pack. Refer to "6
Batteries".
Elevation (H.I.) Alert
The LEDs flash quickly with an audio
beep.
The Zone20 H has been bumped or
tripod was moved. Turn off Zone20 H
to stop alert check the height of the
laser before beginning to work again.
Allow Zone20 H to re-level and check
the height of the laser.
After two minutes in the alert condi-
tion, the unit will shut off automati-
cally.
Servo Limit Alert
All LEDs flash sequentially.
The Zone20 H is tipped too far to
reach a level position. Re-level the
Zone20 H within the 5 degree self-
levelling range.
This alert will also be displayed any
time the unit is tipped more than 45°
from level. After two minutes in the
alert condition, the unit will shut off
automatically.
5 Hz
+
Problem
Possible Cause(s)
Suggested Solutions
The Zone20 H is
working, but not self-
levelling.
The Zone20 H is in Manual Mode.
The Zone20 H must be in Automatic
Mode to self-level. Set the Zone20 H
to Automatic Mode by pressing the
Automatic/Manual Mode button.
–
In Automatic Mode the X-axis LED
and the Y-axis LED flash green
while levelling.
–
In Manual Mode the X-axis LED
and/or the Y-axis LED are red.
Zone20 H does not turn
on.
The batteries are low or dead.
Check the batteries and change or
charge the batteries if necessary. If
the problem continues, return the
Zone20 H to an authorised service
centre for service.
The distance of the
laser is reduced.
Dirt is reducing the laser output.
Clean the windows of the Zone20 H
and the receiver. If the problem
continues, return the Zone20 H to an
authorised service centre for service.
The laser receiver is not
working properly.
The Zone20 H is not rotating. It may be
levelling or in Elevation Alert.
Check for proper operation of the
Zone20 H.
Refer to the receiver manual
for more information.
The receiver is out of usable range.
Move closer to the Zone20 H.
The batteries of the receiver are low.
Change the receiver batteries.
Elevation Alert function
is not working.
The Elevation Alert function is disabled. The Elevation Alert function is enabled
or disabled by pressing the following
button combination:
With Zone20 H turned on and
rotating, press and hold the Up and
Down Arrow buttons. Then press the
Automatic/Manual Mode button to
enable or disable the Elevation Alert
function. The Zone20 H beeps once to
indicate the change.