background image

13 

 

13 
 

 

 

It is not necessary to set up any ‘syncing’ options although it can easily be accomplished.  
Another Bluetooth partnership can also be set up from your desktop/laptop (assuming they have 
Bluetooth modules) to the Field PC and transfer files that way.  

All of these options (and more) are described in the Field PC’s Reference Guide.  

 

4.2  Updating Firmware 
 

This section describes how to download new firmware revisions to the GK-604 Remote Module. 
If a firmware update is needed, new update files (GK604_RFW.S19) are typically available from 
Geokon via email or by downloading from the Geokon web-site. The steps below describe the 
firmware update procedure: 

 

This file needs to be transferred to the \My Documents folder of the Field PC (using any 
strategy described above). 

 

Turn on the remote and make sure its battery is charged (or it is powered externally).  A 
power supply interruption during a firmware update will make it more difficult to complete the 
update in the field and may require sending the unit back to Geokon.  

 

With the GK-604 readout software running, select 

System

Update Firmware

 and follow 

the on-screen instructions.  It takes several minutes to complete the update, so don’t turn off 
the Field PC or the remote unit. 

 

 

4.3  Installing updated GK-604 Readout Software 

 
As new versions of the GK-604 Inclinometer Readout software become available they will be 
posted to Geokon’s web-site. The installation will overwrite the old program, but will not destroy 
any of your saved data or configuration files.  If in doubt, and as a matter of good computer 
technique, take the time to back up critical data and configuration files BEFORE installing the new 
software. 

 

This file needs to be transferred to the root (\) folder or the \My Documents folder of the Field 
PC (using any strategy described in section 4.1). 

 

 

On the Field PC, tap the Start button and then select File Explorer. Navigate to the location 
of the setup file and tap it. 

 

 

Confirm that you want to install the new program and follow any on-screen instructions.  

 

After the installation is complete you should be able to simply launch the GK-604 software from 
the start menu.

 

 

 

 

Содержание GK-604

Страница 1: ...ut the written consent of Geokon Inc The information contained herein is believed to be accurate and reliable However Geokon Inc assumes no responsibility for errors omissions or misinterpretation The...

Страница 2: ......

Страница 3: ...re are no warranties except as stated herein There are no other warranties expressed or implied including but not limited to the implied warranties of merchantability and of fitness for a particular p...

Страница 4: ......

Страница 5: ...Using the GK 604 Readout Software 5 2 3 Exiting the Program 8 3 Configuring Holes Probes and Projects 9 3 1 Hole Configuration 9 3 2 Probe Configuration 10 3 3 Project Configuration 10 3 4 Compass Pro...

Страница 6: ...eadings Menu 6 Figure 7 Live Readings Screen 6 Figure 8 Save data confirm 7 Figure 9 Auto increment save 7 Figure 10 File Save As Screen 7 Figure 11 Hole Configuration 9 Figure 12 Hole Configuration F...

Страница 7: ...on This simplifies the handling of the system in the field as well as simplifying the transfer of data to your PC workstation for final analysis 1 1 Features Rugged general purpose reliable readout ba...

Страница 8: ...e familiarize yourself with the Field PC see the included CD Reference Manual and the Windows Mobile OS It is assumed in the instructions below that you can launch applications from the Start button i...

Страница 9: ...the remote Read about setting up a Bluetooth partnership in Chapter 9 of the Field PC s Reference Guide Several ways to start the Bluetooth Manager 2 Once in the Bluetooth Settings Manager click on th...

Страница 10: ...n will momentarily display the prompt to the right and then return to the Bluetooth Devices screen 6 Click on the COM Ports tab If the Geokon device is already assigned to a COM Port the partnership p...

Страница 11: ...t launch the application displays the error shown in figure 3 then the following options should be considered Make sure the remote is turned on blue light blinking Select the System option and Connect...

Страница 12: ...rt of a survey the level is set to the Starting Level configured for a particular hole Pressing the Record button with a finger or tap of the stylus records that set of A B values and automatically ch...

Страница 13: ...Figure 8 Save data confirm o If Yes is selected you then will be given the choice of saving with the auto increment suffix on the standard filename see figure 9 Selecting Yes again causes the save ope...

Страница 14: ...y the remote will time out and shut off This option retains any readings that haven t been saved to a file simply re activate the GK 604 program and pick up where you left off Selecting the Readings E...

Страница 15: ...board icon bottom of the screen to bring up the on screen keyboard Use it to edit the Hole ID name 9 Probe Number Select the Probe Number or name from the drop down list This associates a hole with a...

Страница 16: ...set of readings you ll see the effect when you go to Live Readings and the readings which are saved in this session OK Tapping OK updates the current session and saves the information to the probe con...

Страница 17: ...at a Compass Probe has been selected see figure 16 The software is designed to work only with the Geokon 6005 3 Spiral Indicator Probe Only one channel A is read and displayed on the Live Readings scr...

Страница 18: ...have to be transferred are the GTilt data files although archiving the others on a master PC is recommended In either case this is easily accomplished several different ways Connecting the Field PC to...

Страница 19: ...field and may require sending the unit back to Geokon With the GK 604 readout software running select System Update Firmware and follow the on screen instructions It takes several minutes to complete...

Отзывы: