66
APPENDIX D. DATA FILE FORMATS
D.1 Raw Data Text Report
When exporting, “raw” text data is the default for the Extended Format options of the “Export
Data Menu” (see Section 3.6.2.1).
2013,140,10,28,28,.83,21.8,9196.9,0.0,0.0,0.0,0.0,0.0,9196.9,1
2013,140,10,28,38,.4,21.8,9545.7,0.0,0.0,0.0,0.0,0.0,9371.3,2
2013,140,10,28,48,.65,21.8,9345.8,0.0,0.0,0.0,0.0,0.0,9362.8,3
2013,140,10,28,58,.8,21.8,9218.6,0.0,0.0,0.0,0.0,0.0,9326.7,4
2013,140,10,29,8,1.27,21.8,8842.8,0.0,0.0,0.0,0.0,0.0,9230.0,5
2013,140,10,29,18,2.39,21.8,7929.2,0.0,0.0,0.0,0.0,0.0,9013.2,6
2013,140,10,29,28,3.03,21.8,7405.9,0.0,0.0,0.0,0.0,0.0,8783.5,7
2013,140,10,29,38,.01,21.8,9866.1,0.0,0.0,0.0,0.0,0.0,8918.9,8
2013,140,10,29,48,.01,21.9,9863.3,0.0,0.0,0.0,0.0,0.0,9023.8,9
2013,140,10,29,58,2.33,22.9,7977.8,0.0,0.0,0.0,0.0,0.0,8919.2,10
2013,140,10,30,8,1.74,23.5,8458.7,0.0,0.0,0.0,0.0,0.0,8877.3,11
2013,140,10,30,18,.03,23.5,9847.6,0.0,0.0,0.0,0.0,0.0,8958.2,12
The comma-delineated columns above represent the following:
Column 1 represents the year when the array was stored
Column 2 represents the Julian day when the array was stored
Column 3 represents the hour when the array was stored
Column 4 represents the minute when the array was stored
Column 5 represents the second when the array was stored
Column 6 represents the vibrating wire reading in engineering unit if applicable
Column 7 represents the sensor temperature in degrees C or degrees F
Column 8 represents the raw vibrating wire reading in digits (cell 1)
Column 9 represents the raw vibrating wire reading in digits (cell 2)
Column 10 represents the raw vibrating wire reading in digits (cell 3)
Column 11 represents the raw vibrating wire reading in digits (cell 4)
Column 12 represents the raw vibrating wire reading in digits (cell 5)
Column 13 represents the raw vibrating wire reading in digits (cell 6)
Column 14 represents the raw vibrating wire reading in digits (average of 1 – 6 above)
Column 15 represents the array number
Note:
The number (and definition) of columns may change as “Export Data→Extended Format”
options are changed (see Figure 62 in Section 3.6.2.1).
Содержание GK-405
Страница 2: ......
Страница 4: ......
Страница 20: ...12 Figure 17 Windows Mobile Device Center ...
Страница 64: ...56 Figure 82 Bluetooth Settings Window COM Ports Tab Figure 83 Remote Connect With ...