6
| INSTALLATION | GEOKON
Lower the final sensor into the casing and position the suspension bracket on
top of the casing. It is important that the top rim of the casing be relatively
square to prevent any side interference with the wheel assembly of the top
sensor.
The safety cable can now be tied off at the top of the casing and the signal cable
can be run to the readout location. Readings can be taken immediately after
installation, but it is recommended that the system be allowed to stabilize for a
few hours before recording the zero readings.
2.3
MODEL 8020-38 RS-485 TO TTL/USB CONVERTER
GEOKON
makes the Model 8020-38 Addressable Bus Converter for connecting
addressable strings to personal computers, readouts, dataloggers, and
programmable logic controllers. The converter acts as a bridge using the TTL or
USB protocols between readers and the
GEOKON
RS-485-enabled sensor strings.
For more information, please refer to the Model 8020-38 instruction manual.
FIGURE 13:
Model 8020-38 RS-485 to TTL/USB Converter
Note:
The datalogger you use must have the appropriate port available.
■
If your datalogger does not have built-in RS-485 communications, connect
the wiring using the diagram in Figure 14.
■
If your datalogger has built-in RS-485 communications, connect the wiring
using the diagram in Figure 15.
FIGURE 15:
Wiring of Datalogger with built-in RS-485 Conversion
FIGURE 14:
Wiring of Datalogger without
built-in RS-485 Conversion