MODEL 6150F MEMS DIGITAL ADDRESSABLE IN-PLACE INCLINOMETER
| INSTALLATION |
3
2.2
ASSEMBLY
2.2.1
SEGMENT ASSEMBLY
Each tilt sensor is supplied with fasteners attached, and with a connecting tube
unattached. To complete the assembly of each segment, do the following:
1.
Remove the nut/bolt fasteners from the tilt sensor.
2.
Connect the spacer tube to the connector at the bottom of the tilt sensor.
3.
Fasten the tube to the sensor using the nuts/bolts removed in step 1.
4.
Repeat steps 1-3 for each tilt sensor/spacer tube set.
FIGURE 5:
Connect the Segment Assembly
PLEASE NOTE:
□
The one-inch cap screws used in the assembly procedure are installed in the
connecting tubes at the factory and must be removed before attaching the
tubing.
□
The string will ship with a few spare cap screws and nuts. The shorter 3/8"
cap screws are spares for the screws that attach the wheel assemblies.
□
Where the spacing of the sensors is too long for a continuous length of
tubing, connect two tubes together using the 6300-7 Tube Coupling (see
the figure below). Use the one-inch cap screws and nuts to secure this
connection.
FIGURE 6:
6300-7 Tube Coupling
□
Use Loctite 222 thread locking compound on all threaded
connections.
2.2.2 BOTTOM WHEEL ASSEMBLY
The bottom wheel assembly, Model 6300-5, has no universal joint, only a swivel.
Attach this wheel assembly to the bottom segment using the provided
hardware.
Connecting Tube
Tilt Sensor
Tube Coupling
Connecting Tube
Connecting Tube