![Geobrugg GBE-100A Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/geobrugg/gbe-100a/gbe-100a_product-manual_2214460011.webp)
Page 11/41
© Geobrugg Gruppe, CH-8590 Romanshorn, Switzerland
GBE-100A / 06
Wire rope di-
ameter
[mm]
Size of the
wire rope
clip
Required
number of
wire rope
clips
distance
e
[mm]
Wrench
size
Distance
Required
tightening
torque lubri-
cated
[Nm]
Required
tightening
torque
unlubricated
[Nm]
11 - 12
7/16“
3
48 - 96
22
40
110
16
5/8“
3
52 - 104
24
90
170
Table 1
Wire ropes must be installed with the required tightening torque.
A visible contusion of the wire ropes positively indicates that the wire rope clips have been tightened to
the required tightening torque.
Wire ropes that have not been damaged can be used again, but the threads and the saddle, in particular,
must be inspected for any damage.
After the first load application the tightening torque has to be checked and if
not fulfilled adjusted to the required value.