15
EN
APPLICATION DEMONSTRATION
SPECIAL FEATURE WITHIN THE RANGE OF 0° - 90°
O-setting in any position required:
In the range between 0° and 90° the ZERO layer can be defined in any position.
Start the calibration function in the position required (press
CAL / REF
longer than 3 sec.) -
wait 3 sec. - press
CAL / REF
again - wait 3 sec. - press
CAL
again - finalized.
Do not turn the S-Digit 60WL
+
/ S-Digit 120WL
+
during this process.
Now the ZERO layer is defined in the new position and the application required can be started.
ATTENTION:
We recommend to define the ZERO layer in the horizontal position again when you have finished your
application. Otherwise it may happen that for the following measurements the results can be complete-
ly wrong (e.g. when you work the next day or if another user is working with the unit).