15
Selection of high / low alarm
Permanent measurements
TECHNICAL DATA
Distance : Spot Size (D:S)
10 : 1
Measuring range
-35°C - +800°C
Icon “Out of measuring range”
„__“
Temperature display
(-) Minus
( ) Plus
Resolution display
0,1°C
Accuracy targets
+18 °C to + 28°C
80 % RH
-35°C to +20°C
± 2,5°C
+20°C to +300°C
± 1,0 %
+300°C to +800°C
± 1,5 %
Response time
0,3 sec
Spectral response
8-
14 µm
Emissivity adjustable
0,10 to 1,0
Laser diode
< 1mW
Wave length
630 – 670 nm
Laser class
2
Operating temperature
0°C to + 50°C
Storage temperature
-10°C to -60°C
Rel. humidity operation
10 % to 90 %
Rel. humidity storage
< 80 %
Power supply
9V battery
Dimensions
160 x 42 x 82 mm
Automatic power off
7 sec
Weight
176 g
Distance (D) : Spot Size (S)
12.5mm @ 125mm
250mm
25mm @
0.5in @ 5.0in.
1in @10in.
S
D
D:S= 10:1
Содержание FIRT 800-Pocket
Страница 2: ...2...
Страница 32: ...32 d une utilisation inad quate ou en liaison avec des produits d autres fabricants...