2. Function

2.1 Function description Optima 180

The flow diagram shows the location of the sensors, while 

the circuit board shows the relay outputs and the other 
outputs for connecting fan and control panel.

Vanvex Lite sanitary hot water heat pump:

Vanvex Lite is an independent sanitary hot water heat 
pump to be installed in rooms that are not part of the 
living space, e.g. basement rooms.
The only requirement to the room is that the air 
temperature stays between 8°C and 35°C. 
We recommend basement rooms because even during 
the winter heat is supplied from the surrounding soil layer.

Heat pump operation

The control starts the compressor shortly after hot water 
has been tapped. The compressor will run until the entire 
tank has been heated to the set temperature again. 

Usually the heat pump can produce a sufficient amount of 

hot tap water covering the needs of a common family.

Water heating:

When hot water is drawn off, the tank will be refilled 

with cold water at the bottom. A sensor measures the 
temperature at the bottom of the tank and starts the 
compressor if the temperature has fallen 5°C below 
the set temperature. The compressor stops, when the 
water has been heated to the set temperature. While 
the compressor operates, the fan runs and circulates air 
through the cooling coil. 

Fan operation:

The operating valve can be adjusted between 0-100%.

2.2 Extra Capacity

If a situation should occur where the heat pump is not 
capable of producing enough hot tap water (more people 
in the house), an extra electrical cartridge in the container 
can be switched on. Doing so, it is possible to heat up 
more water. It is possible to set the desired temperature 
to which the electrical cartridge should heat up the water. 
(Only use the electrical cartridge when needed, as it 
uses more energy than the compressor). The electrical 
cartridge can be activated manually on the display.

2.3 Operating safety

Highpressure switch:

To prevent the compressor from exceeding its range of 
operation, there is an integral high pressure switch, which 
interrupts when the pressure is 20 bar in the cooling 
unit. Activate the red reset button once the cause of the 

error has been identified. When the high pressure switch 

interrupts, the red Genvex logo will flash until the reset 

button manually or the pressure has fallen to 15 baror the 

cause of error has been idenfied. When the high pressure 

switch interrupts, the red light will flash until the reset 

button on the pressure switch is activated. In order to 
prevent a repetition of a pressure switch error, the water 
may be set 2-3 °C lower.

Operation description:

By setting voltage to the system the display will count 5 
seconds up after which the control will show the version 
number. When this has been done the water temperature 
will be shown in the  water reservoir (standard indication).
If the water temperature is lower than the setpoint by 
the operating thermostat, the compressor and the fan 
will turn on. The fan wil start with 30% speed and adjust 
the speed until 100% is reached. When the operatigng 
temperature (P3) is reached the compressor and the fan 
will stopp.

Ambient temperature:

If the ambient temperature is under 8°C the compressor 

and the fan will stopp and first restart when the ambient 

temperature is 9°C (however there will go op to 30 minuts 
before the compressor will restart). When the ambient 
temperature is under 8°C the electrical cartridge will 
automatically turn on and turn on/off according to the 
setpoint at the operatign thermostat (P5). The same 
conditions have its effects when the ambient temperature 
is over 35°C, hereby the compressor will restart again by 
34°C  with a delay on the compressor.

Safety breaker

If an error occurs at the electrical cartridge, the safety 
breaker trips. Resetting the safety breaker may be done 
by breaking the small button in the centre. 

(

When working on the heat pump, always 

make sure that the power supply is 

disconnected.

Any work on this unit may only be carried 

out by trained personnel!)

2.4 Warnings

 

Pressure switch error:

When the high pressure switch trips, the red Genvex logo 

will flash until the red pressure switch is reset.

Содержание Vanvex Lite Optima 150

Страница 1: ...Version 1 03 0310 User Manual Vanvex Lite Optima 150 Domestic Hot Water Heat Pump GB...

Страница 2: ...ty 5 2 3 Operation safety 5 2 4 Warnings 5 3 Maintaining 3 1 Communication box 6 3 2 Cooling System and fan 6 3 3 Water circuit and tank 6 3 4 Cancelling operation 6 4 Fault finding 4 1 Highpressure s...

Страница 3: ...P3 Operating thermostat for heatpump The required sanitary water temperature may be set between 0 55 C which is heated up by the heat pump Factory setting 52 C Max water temperature 55 C P5 Operating...

Страница 4: ...t this valve between 0 100 Factory setting 0 E21 TX set To avoid too high operating pressures in the cooling system the system output must be reduced for the remaining part of the heating period This...

Страница 5: ...its range of operation there is an integral high pressure switch which interrupts when the pressure is 20 bar in the cooling unit Activate the red reset button once the cause of the error has been ide...

Страница 6: ...rn valve which is fitted before the safety valve on the cold water pipe prevents the water from flowing back into the cold water pipe This means that the pressure in the tank will increase to the maxi...

Страница 7: ...aker for electrical cartridge The safety breaker protects the equipment against overheating during heating with the electrical cartridge The safety breaker is mounted on the heater If the adjusted val...

Страница 8: ...um Artiklima bvba B 9220 Hamme Tel 32 0 52 41 25 41 Fax 32 0 52 41 29 66 E Mail info artiklima be Great Britain Total Home Environment Ltd GB Moreton in Marsh GL 56 0JQ Tel 44 0 845 260 0123 Fax 44 0...

Отзывы: