1. Users guide

Optima 150 comes with a factory setup, which enables an 
immediate start of the unit. The factory setup is basic and 
must be adjusted to the operational requirements and 
demands of the individual home, in order to obtain the 

optimum operating benefit from the unit.

1.1 Use

Users menu

The value of a menu item is shown when pressing the 
key/key combination below. The value may be changed 
with the arrows when the key/key combination is held 
down simultaneously. The control will return to standard 
indication if no buttons have been pressed for app. 15 
seconds.

P1: Heat Pump ON/OFF 

On this buttom is it possible to change the function 
between: standby and automatic operation after 
setpoint P3. (Step 0, Step 1).
Step 0: The heat pump is now off and only the 
control is active.
Step 1: The heat pump is in operation mode and 
drives after setpoint thermostat P3.

P2: Operation for the electrical cartridge 

The heat pump comes with an extra electrical 
cartridge for heating of the sanitary hot water. 
On this buttom is it possible to turn on the the 
electrical cartridge if required. By adjusting the 
setpoint to 1 the electrical cartridge will turn on 
after setpoint P5 (operating thermostat for the 
electrical cartridge). The electrical cartridge is not 
on if this setpoint it set to 0.
Note! When the ambient temperature is under 8°C 
or over 35°C the electrical cartridge will turn on 
even if P2 = 0.

P3: Operating thermostat for heatpump

 

The required sanitary water temperature may be 
set between 0 - 55 °C, which is heated up by the 
heat pump.
Factory setting: 52°C
Max.. water temperature: 55°C

P5: Operating thermostat for the electrical 
cartridge

The sanitary water temperature may be adjusted 
between 0 - 65 °C. The electric cartridge solely 
heats the top half of the container, while the heat 
pump still heats the lower half of the container.
Factory setting: 50°C

Display indication

It is possible to view various temperatures in 
the display, by pressing the arrows until the 
requesteed temperature is indicated. After 
app. 5 seconds, the temperature is shown. 
The temperature is shown for app. 30 seconds 
until the display returns to standard. Following 
temperatures may be indicated: 

T5: Ambient temperature
T6: Cooling coil
T7: Sanitary water top
T8: Sanitary water buttom

1.2 Altering the operation data in the 
operating menu

Usually, the display shows the water temperature. 

Press (arrow up) and (arrow down) simultaneously for 
app.10 seconds in order to enter the operating menu. The 

display will now show the first point E0 in the operating 

menu. The operating menu will automatically close and 
return to the main menu if a button has not been pressed 
for 15 sec.
If you wish to scroll through the operating menu, it may 
be done by pressing (arrow up) or (arrow down). The 
value of a point is shown when pressing (temp button). 
The value may be changed with the (arrow up) or (arrow 
down) while simultaneously pressing (temp button). The 
control will return to standard indication if no buttons have 
been pressed for app. 15 seconds.

Содержание Vanvex Lite Optima 150

Страница 1: ...Version 1 03 0310 User Manual Vanvex Lite Optima 150 Domestic Hot Water Heat Pump GB...

Страница 2: ...ty 5 2 3 Operation safety 5 2 4 Warnings 5 3 Maintaining 3 1 Communication box 6 3 2 Cooling System and fan 6 3 3 Water circuit and tank 6 3 4 Cancelling operation 6 4 Fault finding 4 1 Highpressure s...

Страница 3: ...P3 Operating thermostat for heatpump The required sanitary water temperature may be set between 0 55 C which is heated up by the heat pump Factory setting 52 C Max water temperature 55 C P5 Operating...

Страница 4: ...t this valve between 0 100 Factory setting 0 E21 TX set To avoid too high operating pressures in the cooling system the system output must be reduced for the remaining part of the heating period This...

Страница 5: ...its range of operation there is an integral high pressure switch which interrupts when the pressure is 20 bar in the cooling unit Activate the red reset button once the cause of the error has been ide...

Страница 6: ...rn valve which is fitted before the safety valve on the cold water pipe prevents the water from flowing back into the cold water pipe This means that the pressure in the tank will increase to the maxi...

Страница 7: ...aker for electrical cartridge The safety breaker protects the equipment against overheating during heating with the electrical cartridge The safety breaker is mounted on the heater If the adjusted val...

Страница 8: ...um Artiklima bvba B 9220 Hamme Tel 32 0 52 41 25 41 Fax 32 0 52 41 29 66 E Mail info artiklima be Great Britain Total Home Environment Ltd GB Moreton in Marsh GL 56 0JQ Tel 44 0 845 260 0123 Fax 44 0...

Отзывы: