ELECTRICAL DIAGRAM – OPT301

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

L1

L2

L3

L6

L8

L11

H2

H3

H7

H6

H8

H9

H17

H16

ES960C

PE

PE

L17

A

B

Q

1=

 1.

6A

Q

2=

 2.

5A

H1

L4

Q3= 0.5A

Q4= 0.5A

Q1= H8,H9,H10,H11,
       H12,H13,H14,
       H15,H16,H17

Q2= H6,H7,H9

Q3= L1-L17

Q4= L1-L17

Q5= H4, H5

H4

H5

H10

H11

H12

H14

H13

H15

L5

L9

Q

5=

 6.

3A

L10

L16

C

D

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

L1 = Potential free input for optional:
        Humidistat, Extractor hood ,CO2
L2 = Optima Display
L3 = Sensors T1,T3,T4,T7
L4 = Not in use
L5 = Not in use
L6 = Sensors T5,T6,T8,T9
L8 = External stop
L9 = Fan RPM
L10 = Modulating Pre / Reheating
L11 = 0-10V Motorvalve  Reheating 
          0-10V Belimo LM230ASR bypass
L16 = Not in use
L17 = 0-10V extract air fan and
          0-10V supply air fan

H1 = Mains connection 230 VAC
H2 = (R2) Electric Reheater Step A 230VAC
H3 = (R3) Electric Preheater 230VAC
H2,H3 = Max. load total 1800W
H4 = (R1) High pressure switch
H5 = (R1) Compressor230VAC
H6 = (R10) Motorvalve Reheating,
                   Belimo LM230ASR 230VAC
H7 = (R10) Fan, extract air 230VAC
H8 = (R12) Not in use
H9 = (R10) Fan, supply air 230VAC
H10 = (R4) Soleniod valve MA4 Defrost 230VAC
H11 = (R7) Extra relay 230VAC
H12 = (R5) Electric Reheater Step B 230VAC
H13 = (R5) Electric Reheater Step B 230VAC
H14 = (R6) Electric Reheater Step C 230VAC
H15 = (R6) Electric Reheater Step C 230VAC
H16 = (R8) Soleniod valve MA7 Cooling 230VAC 
H17 = (R9) AUX relay 230VAC

A = LED Flash - Power on 
B = LED Flash - Communication to Optima Display

Optima 301

Содержание PREMIUM PREHEAT 250

Страница 1: ...INSTALLATION MANUAL PREMIUM PREHEAT 250 300 500 Air air heat recovery ventilation heat pump...

Страница 2: ...attics 6 Insulation of ducts in warm rooms 7 Electrical connection 7 Starting up the unit 7 Optimal adjustment of the ventilation system 8 Maintenance of the system 8 Trouble shooting 10 PCB layout 1...

Страница 3: ...n tray of the unit to ensure that it flows out freely 6 If the water trap is fitted in a place where there is a risk that the temperature drops below 0 C then an electric heating element with a thermo...

Страница 4: ...ted on the top of the unit The electrical box is located on the top of the unit The unit has 2 condensation drains both of which must be connected to a suitable drain The unit must be placed on a soli...

Страница 5: ...s installing a silencer between the two rooms It is recommended that the air speeds in the ducts be dimensioned low enough so that there is no noise from the supply air and extract air valves When pos...

Страница 6: ...checked and then filled with water if necessary Insulation of ducts in cold attics In order to benefit from the unit s high heat recovery rate it is necessary that the ducts are insulated properly Gen...

Страница 7: ...nit and control panel must be a 4 wire min 0 25 mm2 cable with a maximum length of 50 m Starting up the system To achieve optimum operation of the system it must be adjusted with air measuring equipme...

Страница 8: ...ting Maintenance of the system Filters When the filter timer reaches the set value for filter change Alarm will show in the screen saver and Chg filter will flash This means that it is time to clean c...

Страница 9: ...nger Wash in lukewarm soapy water and rinse using a hand shower if necessary Plastic exchanger No cleaning with fluids including water only careful dust removal from air intake surfaces with a househo...

Страница 10: ...been installed correctly No supply air Error Faulty supply air fan Clogged supply air filter Clogged fresh air grill due to dirt and leaves during the fall and snow and ice during the winter Fuse on...

Страница 11: ...sors T1 T3 T4 T7 L4 Not in use L5 Not in use L6 Sensors T5 T6 T8 T9 L8 External stop L9 Fan RPM L10 Modulating Pre Reheating L11 0 10V Motorvalve Reheating 0 10V Belimo LM230ASR bypass L16 Not in use...

Страница 12: ...fan Supply air Blue Yellow EC fan Extract air 1x230V 50Hz Black Black Blue Blue Yellow green Yellow green Belimo LM230ASR Bypass EC fan Supply air 1x230V 50Hz Electric Reheater Step A 1x230V 50Hz Sol...

Страница 13: ...r Fortluft Indbl sning Supply air Zuluft T1 T7 T5 T6 T4 T3 M2 M2 M1 Fordamper Evaporator Verdampfer Kondensator Condenser Verfl ssiger Forvarme Preheater Vorv rme Kompressor Compressor Verdichter HP H...

Страница 14: ...nvex The original Danish Ventilation System Genvex is a genuine Danish original We invented the ventilation system more than 40 years ago and we are still ahead of the pack when it comes to developmen...

Отзывы: