5
INSTALLATION
IMPORTANT!
The unit may only be used in connection with an electrical
installation executed properly with grounding. It must also
be ensured that the earth connection of the electrical
installation is matched to the earth plug of the unit.
These instructions must be followed.
If the installation is
not executed in accordance with these instructions, KVM-
Genvex cannot be held liable for any further damage that is
unrelated to the Genvex unit.
KVM-Genvex A/S always recommends careful planning of
the installation space for your Genvex product in relation to
the location of living spaces. As this is a technical product
that contains fans and/or a heat pump, in rare cases, and in
combination with inappropriate installation conditions, it
may cause unsatisfactory noise or vibration nuisance. As a
general rule, it is always recommended installing the
technical system so that it is not located in the immediate
vicinity of a bedroom. Furthermore, when securing the
Genvex unit to the building structure, it is recommended
attaching it to a heavy structural component such as
concrete. It should also be ensured that no sound or vibra-
tions can be transmitted through materials in contact with
the technical system. If there is a risk of propagation of
noise and vibrations, further installation of vibration-
damping material and sound-damping of installation rooms
are recommended.
Wall mounting (vertical connections)
Before starting the installation of the ventilation unit
Make sure that the wall used to hold the ventilation unit is
built in such a way that it is able to support the weight of
the unit. In addition, the wall must be straight and plumb.
1. Before attaching the mounting bracket to the wall,
ensure that the bracket is in the correct position and
that the necessary space and service conditions are
available. Place the mounting bracket level and mark the
positions of all 4 screw holes.
2. Attach the bracket to the wall using screws in all 4
mounting holes.
3. Mount the ventilation unit by hanging it on the mounting
bracket. The recess on the back of the unit is intended
for this.
Once the ventilation unit has been properly attached to the
mounting bracket, lock the unit in place by inserting the
locking screw into the locking hole. The supplied safety
screws must be fully tightened!