Instruction Manual - Clinic 6.90 Compressors
MAN0690001 - 08/2019
troubLESHootINg
faILurE to foLLoW tHE proCEDurES CoNtaINED IN tHIS paragrapH
may CauSE a maLfuNCtIoN of tHE maCHINE aND/or uNDErmINE tHE
SafEty of tHE SamE.
probLEm
CauSE
SoLutIoNS
The machine does
not turn or stops and
does not restart.
No electricity.
•
Check that the switch
(18)
is in pos.
“ON (I)”.
•
Check that the power cord plug
(15)
is working properly and inserted into
the socket.
•
Check that any extension cords used
and the current outlet are operatio-
nal.
•
Check that the switch of the main po-
wer supply is functioning and in pos.
“ON (I)”.
The machine does
not turn or stops and
does not restart.
Intervention of the re-
settable thermal due to
current overload and/or
short circuit.
•
Follow the procedure described in
par. “RESETTABLE THERMAL”.
The machine often
starts again without
the pneumatic plant
is operating.
Air leaks from the pipe or
its pneumatic plant.
•
Check that the pneumatic system is
not damaged.
•
Check the integrity of the pipe con-
nections and air system.