34
www.gentilinair.com
Instruction Manual - Clinic 6.90 Compressors
MAN0690001 - 08/2019
rEf. NamE
fuNCtIoN
1
Air outlet.
¼” G hole for air connection.
2
Tank pressure gauge.
It shows the outlet air pressure set through the regulator.
3
Pressure switch.
It is an electro-pneumatic device (set at min. 6 bar max. 8
bar) fitted onto the pneumatic plant. It is used to control the
automatic start of the machine when the pressure drops to 6
bar and the automatic stop when the pressure reaches 8 bar.
4
Interruttore
“ON (I)-OFF (0)”
Pos. “ON (I)”: Turns on the machine;
Pos. “OFF (0)”: Turns off the machine.
5
Safety valve.
It is a certified safety valve (set at 10.5 bar), installed in the
pneumatic system under the pressure switch. It is used to
discharge the overpressure in the system if the pressure
switch, for any problems, does not function.
The intervention of the safety valve forces the operator to
turn off the machine and request the assistance of the main-
tenance technicians.
Содержание CLINIC 6.90 H