PH Series Instruction Manual 

 

Gentec Electro-Optics Inc.  All rights reserved

 

Aperture 

10 mm diameter 

10 mm diameter 

5 mm diameter 

Active Area 

0.9 cm

2

 

0.9 cm

2

 

0.2 cm

2

 

Response time10-90% 

0.2 sec 

0.2 sec 

0.2 sec 

Beam Position 
Dependence 

±1% @ 780 nm 

 ±3% @ 1064 nm 

±1% @652 nm 

±3% @ 1064 nm 

± 1 % @ 1064 nm 

±3% @ 800 nm 

Noise 

5 pA 

5 pA 

60 pA 

Dimensions 

27.4mm x 38.1mm dia.  27.4mm x 38.1mm dia.  27.4mm x 38.1mm dia. 

Weight 

130 g 

130 g 

130 g 

Sensitivity, typical 

0.5 A/W @ 980 nm 

0.45 A/W @ 850 nm 

0.98 A/W @ 1550 nm 

With attenuator 

PH100-Si - OD1/OD2 

PH100-SiUV - 

OD1/OD2 

PH20-Ge- OD1/OD2 

Maximum Power typ. 
w/ OD-1  

300 mW @ 1064 nm 

25  mW @ 532 nm 

300  mW @ 1064 nm 

Minimum Power

a

  

w/ OD-1 

6 nW @ 980 nm 

6 nW @ 850 nm 

20 nW

  

@ 1550 nm 

Spectral range 
w/ OD-1 

400 to 1100 nm 

400 to 1080 nm

 

900 to 1650 nm 

Maximum Power typ. 
w/ OD-2 

0.75 W @ 1064 nm 

30 mW @ 850 nm 

0.50 W @ 1064 nm 

Minimum Power

a

  

w/ OD-2  

60 nW @ 980 nm 

60 nW @ 850nm 

200 nW @ 1550 nm 

Spectral range 
w/ OD-2 

630 to 1100 nm 

630 to 1080 nm

 

950 to 1650 nm 

Uncertainty w/ OD-1 or 
OD-2 attenuator 

400-1049 nm: ±5% 

1050-1100 nm: ±7% 

400-1049 nm: ±5 

1050-1080 nm: ±7% 

±5% 

 
  
 

Specifications subject to change without notice. 

 
 

Содержание PE10B-Si

Страница 1: ...to obtain a return authorization number Return the material to the appropriate address below Contacting Gentec Electro Optics Inc To help us answer your calls more efficiently please have the model n...

Страница 2: ...idity or surface contaminants exposure to flame solvents or water and connection to improper electrical voltage TABLE OF CONTENTS WARRANTY I First Year Warranty i Lifetime Warranty i TABLE OF CONTENTS...

Страница 3: ...TO DETECTOR DIMENSIONS 3 FIG 1 2 TYPICAL GE TEMPERATURE DEPENDENCE VS THE WAVELENGTH 10 FIG 1 3 TYPICAL SI AND SIUV TEMPERATURE DEPENDENCE VS THE WAVELENGTH 10 FIG 1 4 PH100 SI TYPICAL SPECTRAL RESPON...

Страница 4: ...uoted maximum ranges are average power at the 1064 nm wavelength for PH100 Si and PH20 Ge 532 nm for PH100 SiUV and 850 nm for PH100 SiUV with OD 2 quoted minimum ranges are average power at the 980nm...

Страница 5: ...ific PH and PE Series head Wavelengths are not available where the sensor physical properties don t allow it The Gentec eo monitors use the data in this connector to adjust their characteristics autom...

Страница 6: ...Version 2 0 PH Series Instruction Manual Gentec Electro Optics Inc All rights reserved 3 1 2 2 Dimensions FIG 1 1 PHOTO DETECTOR DIMENSIONS...

Страница 7: ...30 mW 320 mW cm2 1064 nm Minimum Powera 0 6 nW 980 nm 0 6 nW 850 nm 2 nW 1550 nm Damage threshold Maximum Average Power Density 100 W cm 2 100 W cm 2 100 W cm 2 Typical Detector saturation currentb 6...

Страница 8: ...W 980 nm 0 45 A W 850 nm 0 98 A W 1550 nm With attenuator PH100 Si OD1 OD2 PH100 SiUV OD1 OD2 PH20 Ge OD1 OD2 Maximum Power typ w OD 1 300 mW 1064 nm 25 mW 532 nm 300 mW 1064 nm Minimum Power a w OD 1...

Страница 9: ...measurable power M Link 200 W S Link 175 W Maestro 150 W 633nm M Link 32 W S Link 26 W Maestro 22 W 1047 nm Maximum Average Power Density 65 mW cm2 532 nm 320 mW cm2 1064 nm Noise equivalent power 10...

Страница 10: ...Repetition Rate 1000 Hz Max Pulse Width 10 s Maximum Measurable Energy M Link 0 16 J S Link 0 13 J Maestro 0 11 J 633nm M Link 3 2 nJ S Link 2 6 nJ Maestro 2 4 nJ 1047 nm Maximum Energy Density 5 J c...

Страница 11: ...ack protective cover on the detector head before making the offset nulling If you want to subtract the room light do the offset nulling with the cover off 2 2 QUICK POWER MEASUREMENT PROCEDURE This se...

Страница 12: ...component not related to the laser power This will add a systematic error to absolute power measurements This error may disappear from relative power measurements When you subtract two measurements m...

Страница 13: ...0 PH Series Instruction Manual Gentec Electro Optics Inc All rights reserved 10 FIG 1 2 TYPICAL GE TEMPERATURE DEPENDENCE VS THE WAVELENGTH FIG 1 3 TYPICAL SI AND SIUV TEMPERATURE DEPENDENCE VS THE W...

Страница 14: ...saturate the detector To know if the detector is saturated use procedure 4 3 1 Be careful when making the attenuator calibration in pulse mode The peak power must be in the linear region of the photo...

Страница 15: ...esired Wavelength The difference between the desired wavelength and the inferior wavelength 4 5 1 Example You have a PH100 Si and your laser is at 632 8 nm See your CERTIFICATE OF CALIBRATION for the...

Страница 16: ...Version 2 0 PH Series Instruction Manual Gentec Electro Optics Inc All rights reserved 13 FIG 1 4 PH100 SI TYPICAL SPECTRAL RESPONSE FIG 1 5 PH100 SIUV PH10B SI PE10B SI TYPICAL SPECTRAL RESPONSE...

Страница 17: ...Version 2 0 PH Series Instruction Manual Gentec Electro Optics Inc All rights reserved 14 FIG 1 6 PH20 GE PH5B GE PE5B GE TYPICAL SPECTRAL RESPONSE...

Страница 18: ...center when the detector reaches its end of life Breaking the calibration seal or opening the monitor will void the detector warranty The complete Detector contains 1 Detector with wires or DB 15 1 i...

Страница 19: ...Version 2 0 PH Series Instruction Manual Gentec Electro Optics Inc All rights reserved 16...

Отзывы: