13
USING THE GENERATOR
Service environment of the generator
1
•
Applicable temperature: -5°C ~ 40°C;
•
Applicable humidity: below 95%;
•
Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m).
Standard atmospheric condition
•
Ambient temperature Tr: 298k (25°C)
•
Relative air humidity
Ф
r: 30%
•
Absolute atmospheric pressure Pr: 100kPa
When actual environmental condition is inconsistent with the condition of output power of the generator
set:
•
Every 5°C of increase in ambient temperature will reduce the power of generator by about 2%.
•
Every 30% of increase in relative humidity of air will reduce the power of generator by about 1.5%.
•
Every 300 m rising of ASL will reduce the power the generator by about 4.5%.
Generator wiring
2
•
When the generator is connected to household power source as a backup power supply, the connection shall be
carried out by a professional electrician or a person familiar with electricity.
•
After connecting the load to the generator, check carefully whether electrical connection is safe and reliable.
Improper electrical connection may cause generator damage, burning or fire.
•
Avoid connecting this generator to commercial power outlet.
•
When extending the cable, be sure not to exceed its length.
①
60m cross-section area is 1.5mm²
②
100m cross-section area is 2.5mm²
•
The appearance of extension cable shall be protected by a layer of tough and elastic rubber cover (IEC25) or
other substitutes.
OK
OK
Содержание GM1200i
Страница 7: ...6 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS ...
Страница 23: ...22 TROUBLESHOOTING ...
Страница 24: ...23 TROUBLESHOOTING ...
Страница 26: ...25 CIRCUIT DIAGRAM GM1200i SCHEMATICS ...
Страница 27: ...26 R CHOOSING A GENERATOR 1 ...