20
STORAGE AND TRANSPORT
Generator storage
1
If it is stored long-term, in order to prevent aging, you shall take some storage measures.
Follow the shutdown steps to shut down the generator
.
1.
Open fuel tank cap, to take out fuel filter screen.
Pump all fuel in fuel tank into special fuel tank,
and then reassemble fuel tank cap back.
2.
Start up the engine to burn off fuel in the carburetor, and then shut it down.
3.
Tip:
Do not connect any electrical equipment. Running time of the engine depends on remaining fuel in the fuel
tank.
Remove air filter service panel and enter carburetor. Locate the clear plastic
hose from the float that is exiting out the bottom of the generator, and place
a suitable container under it to catch the drained fuel.
4.
Loosen the carburetor drain screws until you see fuel draining from the
carburetor.
5.
Allow fuel to drain into the container and tighten the drain screws on the
carburetor. Install the engine service panel.
6.
After the engine is completely cooled, switch off ventilation knob of fuel tank cap.
7.