Genius JA388 Скачать руководство пользователя страница 8

6

ENGLISH

Opening/closing time is established by a learning procedure
which varies slightly according to whether you are using limit-
switches.

6.3.1. LEARNING OF NORMAL TIMES

- SIMPLE LEARNING:

Check if the leaves are closed, and then press F push-button for
one second: DL10 LED begins flashing and the leaves begin the
opening movement.
Wait for the leaf to reach the opening stop limit and then supply
an OPEN A pulse (with the radio control or with the key controlled
push-button) to stop the movement: the leaves stop and the
DL10 LED stops flashing.
The procedure has ended and the gate is ready to operate.
Next pulse closes leaves and they stop on automaticaly reaching
closed position.

- ADVANCED COMPLETE LEARNING:

Check if the leaves are closed, and then press F push-button for
more than 3 seconds: DL10 LED begins flashing and the leaf 1
begins the opening movement. The following functions can be
commanded by the OPEN A pulses (by radio control or key
controlled push-button):

1° OPEN - Deceleration at opening of leaf 1

2° OPEN - Leaf 1 stops at opening and leaf 2 begins its

opening movement

3° OPEN - Deceleration at opening of leaf 2

4° OPEN - Leaf 2 stops at opening and immediately begins

its closing movement

5° OPEN - Deceleration at closing of leaf 2

6° OPEN - Leaf 2 stops at closing and leaf 1 begins its closing

movement

7° OPEN - Deceleration at closing of leaf 1

8° OPEN - Leaf 1 stops at closing

The DL10 LED stops flashing and the gate is ready for normal
operation.

Notes:

•If you wish to eliminate deceleration in certain stages,

wait for the leaf to reach its stop-limit and supply 2
consecutive Open pulses (by 1 second).

•If only one leaf is present, the entire sequence must

nevertheless be effected. When the leaf has finished
opening, supply 5 Open pulses until the leaf begins to
close, and then resume normal operation.

•It wind effected areas it is best to allow 2 second after

the leaf reaches open stop befor supplying  Open A to
ensure full closing.

WARNING:

 during the learning procedure, the  safety devices are

disabled! Therefore any transit must be  avoided in the leaf
movement area when this operation  is carried out.

6.2. ROTATION DIRECTION AND FORCE CHECK

1)

Program the functions of the control board according to
need, as shown in Chapter 5.

2)

Cut power to the electronic control equipment.

3)

Release the operators and manually move the gate to the
mid-point of the opening angle.

4)

Re-lock the operators.

5)

Restore power.

6)

Send and opening command on the OPEN A input (fig.2)
and check if the gate leaves are being commanded to
open.

N.B.:

If the first OPEN A pulse commands a closing, cut power and
change over the phases of the electric motor (brown and
black wires) on the terminal board.

7)

Check power setting of the motors and, if necessary, modify
it (see Chapter 5.1).

N.B.:

If using hydraulic operators, force should be programmed to
maximum level (8)

8)

Stop leaf movement with a STOP command.

9)

Release the operators, close the leaves and re-lock the
operators.

6.3. LEARNING OF OPERATING TIMES

6.3.2. LEARNING WITH LIMIT-SWITCHES

Learning with limit-switches can be done in two different ways:

- SIMPLE LEARNING:

Check if the leaves are closed, and then press F push-button for
1 second: DL10 LED begins flashing and the leaves begin the
opening movement.
The motors stop automatically when the opening limit-switches
are reached, but an OPEN A pulse must be given (by radio
control or key push-button) to end the cycle; the leaves stop and
the DL10 LED stops flashing.
The procedure has ended and the gate is ready to operate.
Next pulse closes leaves and they stop on automaticaly reaching
closed position.

- ADVANCED COMPLETE LEARNING:

Check if the leaves are closed, and then press the F push-button
for more than 3 seconds: DL10 LED begins flashing and leaf 1
begins the opening movement. The leaves automatically
decelerate when they reach the limit-switches, and therefore, it
is sufficient to inform the equipment that the stop limits have been
reached by means of OPEN A pulses (by radio control or key push-
button):

FCA1  -

Deceleration at opening of leaf 1

1° OPEN - Leaf 1 stops at opening and leaf 2 begins its

opening movement

FCA2  -

Deceleration at opening of leaf 2

2° OPEN - Leaf 2 stops at opening and immediately begins

its closing movement

FCC2    -

Deceleration at closing of leaf 2

3° OPEN - Leaf 2 stops at closing and leaf 1 begins its closing

movement

FCC1    -

Deceleration at closing of leaf 1

4° OPEN - Leaf 1 stops at closing

the DL10 LED stops flashing and the gate is ready for normal
operation

Notes:

•If you wish to eliminate deceleration in some stages,

you must supply an Open pulse within 1 second of
reaching the limit-switch.

•If some limit-switches are not installed, start the

corresponding deceleration by supplying an Open
pulse (which replaces the limit-switch).

•If only one leaf is present, the entire sequence must

nevertheless be effected. When the leaf has finished
opening, supply 5 Open pulses until the leaf begins to
close, and then resume normal operation.

•It wind effected areas it is best to allow 2 second after

the leaf reaches open stop befor supplying  Open A to
ensure full closing.

6.3.3. LEARNING TIMES WITH ENCODER

Learning with the encoder can be done in two different ways:

- SIMPLE LEARNING:

Check if the leaves are closed, and then press F push-button for
1 second: DL10 LED begins flashing and the leaves begin the
opening movement.
The movement stops automatically when the opening stop limit
is reached and the DL10 LED stops flashing.
The procedure has ended and the gate is ready to operate,
using fixed deceleration.

- COMPLETE LEARNING:

Check if the leaves are closed, and then press the F push-button
for more than 3 seconds: DL10 LED begins flashing and leaf 1
begins the opening movement. The following functions can be
commanded by the OPEN A pulses (by radio control or key push-
button):

1° OPEN - Leaf 1 Decelerates at opening (it stops

automatically on reaching the stop limit)

2°  OPEN  - Leaf 2 opening movement begins
3° OPEN - Leaf 2 Decelerates at opening (it stops

automatically on reaching the stop limit)

4°  OPEN  - Leaf 2 closing movement begins

Содержание JA388

Страница 1: ...JA388 CONTROL BOARD FOR 115V HINGED GATES EQUIPO ELECTR NICO PARA PORTONES DE TIPO BATIENTE 115V USE AND INSTALLATION INSTRUCTIONS INSTRUCCIONES PARA EL USO NORMAS DE INSTALACI N...

Страница 2: ...inflammablegasorfumesisaseriousdangertosafety 8 ThemechanicalpartsmustconformtotheprovisionsofStandardsEN12604 andEN12605 For non EU countries to obtain an adequate level of safety the Standards ment...

Страница 3: ...i automatic B Dead man C Stepped semi automatic Opening closing time Programmable from 0 to 120 s Pause time 0 10 20 30 60 120 s Closing leaf delay 0 5 10 20 s Opening leaf delay 2 s Can be disabled w...

Страница 4: ...6 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX CL TX CL 1 2 5 4 3 1 2 RX OP CL TX OP CL Fig 3 Opening closing safety devices they operate during the gate opening and clos...

Страница 5: ...Total Opening command N O any pulse generator push button detector etc which byclosingacontact commands opening and or closing of both gate leaves Toinstallseveralfullopeningpulsegenerators connect t...

Страница 6: ...this terminal and the 24V supply To avoid compromising correct operation of the system do not exceed the indicated power LOCK Terminal 21 Power supply to electric lock If required necessary connect a...

Страница 7: ...OFF OFF 5 6 ON ON OFF ON SW3 ON ON ON ON OFF OFF 7 OFF ON OFF 8 MAX OFF OFF OFF 1 2 3 4 5 6 7 8 9 10 11 12 1 MIN 2 3 4 SW4 ON OFF ON OFF SW5 ON ON OFF OFF 5 6 ON ON OFF ON SW6 ON ON ON ON OFF OFF 7 O...

Страница 8: ...h a STOP command 9 Release the operators close the leaves and re lock the operators 6 3 LEARNING OF OPERATING TIMES 6 3 2 LEARNINGWITHLIMIT SWITCHES Learning with limit switches can be done in two dif...

Страница 9: ...operation Notes The deceleration pulse should be supplied a little earlier with respect to the stop limit to prevent the leaf reaching it at full speed it would be taken for an obstacle If only one le...

Страница 10: ...s or leaf No effect No effect Closes the leaves or leaf Stops operation No effect OPEN B disabled No effect OPEN A disabled No effect PULSES No effect OPEN B disabled Stops operation OPEN B disabled S...

Страница 11: ...note notes note notas anmerkung...

Страница 12: ...note notes note notas anmerkung...

Страница 13: ...note notes note notas anmerkung...

Страница 14: ...note notes note notas anmerkung...

Страница 15: ...dor C Semiautom tica paso paso Tiempodeapertura cierre Programable de0a120s Tiempodepausa 0 10 20 30 60 120s Tiempoderetardodelahojaencierre 0 5 10 20s Tiempoderetardodelahojaen apertura 2s Puedeexclu...

Страница 16: ...sejado 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX CL TX CL 1 2 5 4 3 1 2 RX OP CL TX OP CL Fig 3 Dispositivos de seguridad en apertura cierre int...

Страница 17: ...contacto manda la apertura y o cierre de ambas hojas de la cancela Para instalar varios emisores de impulso de apertura total conecten los contactos N A en paralelo v ase fig 13 OPEN B Mando de Apertu...

Страница 18: ...sistema no hay que superar la potencia indicada LOCK Alimentaci n electrocerradura Conecten entre este borne y el 24V una eventual electrocerradura 12 V ac 4 6 Conector J2 Conector r pido 5 pins Se ut...

Страница 19: ...FF 1 2 3 4 5 6 7 8 9 10 11 12 1 MIN 2 3 4 SW4 ON OFF ON OFF SW5 ON ON OFF OFF 5 6 ON ON OFF ON SW6 ON ON ON ON OFF OFF 7 OFF ON OFF 8 MAX OFF OFF OFF E SW7 ON SW8 ON A A ON ON OFF ON SW9 ON OFF OFF A...

Страница 20: ...mpulso de Open que sustituye al fin de carrera Si s lo est presente una hoja hay que realizar igualmente toda la secuencia Cuando termina la apertura de la hoja hay que dar 5 impulsos de Open hasta qu...

Страница 21: ...cela est cerrada 2 Abran y mantengan abierto el contacto de Stop 3 Comprueben que el led DL10 est encendido si est apagado el predestello ya est inactivo 4 Presionen el pulsador F durante un instante...

Страница 22: ...bido Ning n efecto si ha de abrir inhibe OPEN Ning n efecto OPEN inhibido encendida Ning n efecto OPEN inhibido Tab 3 d Ning n efecto memoriza OPEN Ning n efecto OPEN A B inhibidos Abre las hojas o la...

Страница 23: ...ra evitar que la automaci n pueda ser accionada involuntariamente HINWEISE F R DEN INSTALLATIONSTECHNIKER ALLGEMEINE SICHERHEITSVORSCHRIFTEN 1 ACHTUNG Um die Sicherheit von Personen zu gew hrleisten s...

Страница 24: ...senziali di sicurezza delle seguenti direttive 73 23 CEE e successiva modifica 93 68 CEE 89 336 CEE e successiva modifica 92 31 CEE e 93 68 CEE Grassobbio 1Marzo2002 L Amministratore Delegato D Gianan...

Отзывы: