Connection of a pair of opening photocells and a pair of
closing photocells
1
2
5
4
3
1
2
RX CL
TX CL
1
2
5
4
3
1
2
RX OP
TX OP
-
-
-
-
+
+
+
+
9 10 11 12 13 14 15 16 17 18 19
OPEN
A
B STP CL OP
FSW
-
-
-
+24V
+
+
-TX
FSW
20 21
W.L.
LOCK
9 10 11 12 13 14 15 16 17 18 19
OPEN
A
B STP CL OP
FSW
-
-
-
+24V
+
+
-TX
FSW
20 21
W.L.
LOCK
1
2
5
4
3
1
2
RX CL1
TX CL1
1
2
5
4
3
1
2
RX CL2
TX CL2
-
+
-
+
Fig. 11
Connection of two pairs of closing photocells
Fig. 10
1
2
5
4
3
1
2
RX
TX
-
+
-
+
9 10 11 12 13 14 15 16 17 18 19
OPEN
A
B STP CL OP
FSW
-
-
-
+24V
+
+
-TX
FSW
20 21
W.L.
LOCK
Fig. 9
Connection of 1 pair of closing photocells
Fig. 12
Fig. 13
Connection of 2 N.C. contacts in series
(e.g. Photocells, Stop)
Connection of 2 N.O. contacts in parallel
(e.g. Open A, Open B)
4.2. Terminal board J3 - Power supply (fig. 2)
PE:
Earth connection
N :
230 V~ power supply ( Neutral )
L :
230 V~ power supply ( Line )
NB.:
For correct operation, the board must be connected to the
earth conductor in the system. Install an adequate differential
thermal breaker (RCD) upstream of the system.
4.3. Terminal board J4 - Motors and flashing lamp (fig. 2)
M1
:
Terminals 1/2/3 = COM/OP/CL: Connection to Motor 1
Can be used in the single-leaf application
M2
:
Terminals 4/5/6 = COM/OP/CL: Connection to Motor 2
Cannot be used in the single-leaf application
LAMP :
Terminals 7/8 = Flashing lamp output ( 230 V ~)
4.4. Terminal board J1 - Accessories (fig. 2)
OPEN A - Terminal 9 plus a negative = "Total Opening"
command (N.O.):
any pulse generator (push-button,
detector, etc.) which, by closing a contact, commands
opening and/or closing of both gate leaves.
To install several full opening pulse generators, connect
the N.O. contacts in parallel (see fig.13).
OPEN B - Terminal 10 plus a negative = "Partial Opening"
command (N.O.) / Closing:
any pulse generator (push-
button, detector, etc.) which, by closing a contact,
commands opening and/or closing of the leaf driven by
motor M1. In the
B
and
C
logics, it always commands
closing of both leaves.
To install several partial opening pulse generators,
connect the N.O. contacts in parallel (see fig.13).
STP - Terminal 11 plus a negative = STOP contact (N.C.):
any
device (e.g. a push-button) which, by opening a
contact, is able to stop gate movement.
To install several STOP devices, connect the N.C. contacts
in series (see fig.12).
NB.:
If STOP devices are not connected, jumper connect
the
STP
terminals and
-
common.
CL FSW - Terminal 12 plus a negative = Closing safety devices
contact (N.C.):
The purpose of the closing safety devices
are to protect the leaf movement area during closing.
During closing, in the
A-SP-E-EP
logics, the safety devices
reverse the movement of the gate leaves, or stop and
reverse the movement when they are released (see
programming of microswitch
DS2 - SW2
). During the closing
cycle in logics
B
and
C
, they interrupt movement. They
never operate during the opening cycle. If the
closing
safety devices
operate when the gate is open, they
prevent the leaf closing movement.
NB.: If no closing safety devices are connected, jumper
connect terminals CL and -TX FSW
(fig. 7).