Genius JA388 Скачать руководство пользователя страница 3

1

ENGLISH

230 VAC

50 Hz

24 Vdc

3 W

J4

J1

J3

PE N L

MAIN

1

2

4

5 6 7 8

COM OP

M1

COM OP

M2 CL

LAMP

9 10 11 12 13 14 15 16 17 18 19

OPEN

A

B STP CL OP

FSW

-

-

-

+24V

+

+

-TX

FSW

20 21

W.L.

LOCK

J5

3

230 VAC

max.60W

12 V ac

J6

22

23

24 25

FC

A

1

FC

C

1

FC

A

2

FC

C

2

C1

M1

C2

M2

3.

LAYOUT AND COMPONENTS

Fig. 1

NB.: Capacitors are supplied with the operators.

Fig. 2

J4

J1

J3

F1

F2

1 2 3 4

9 10 11 12

5 6 7 8

1 2 3 4

PE N L

MAIN

1

2

4

5 6 7 8

COM OP

M1

COM OP

M2 CL

LAMP

9 10 11 12 13 14 15 16 17 18 19

OPEN

A

B STP CL OP

FSW

-

-

-

+24V

+

+

-TX

FSW

J2

F

DL10

OP_A

OP_B

STOP

FSWOP

FSWCL

20 21

W.L.

LOCK

J5

22

23

24 25

FC

A

1

FC

C

1

FC

A

2

FC

C

2

J6

FCA2

FCA1

FCC2

FCC1

TOTALLY OPEN

OPEN LEAF 1

STOP

1.

WARNINGS

Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.

- Install, upstream of the system, a differential thermal breaker

(Residual Current Device) with adequate tripping threshold.

- Connect the earth cable to the appropriate terminal on the J3

connector of the equipment (see fig.2).

- Always separate power cables from control and safety cables

(push-button,  receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).

CONTROL BOARD JA388

4.

ELECTRIC CONNECTIONS

F1

F2

J1

J3

J4

J5

J6

LIMIT-SWITCH

2.

TECHNICAL SPECIFICATIONS

Power supply

115 V~ ( +6%  -10%) - 50 Hz

Absorbed power

10 W

Motor max. load

1200 W

Accessories max. load

0,5 A

Electric lock max. load

15 VA

Operating ambient temperature

-20 °C +55 °C

Protection fuses

2 (see fig. 1)

Function logics

Automatic / Semi-automatic /  "Stepped" safety devices /

Semi-automatic B / Dead-man C / "Stepped" semi-automatic

Opening/closing time

Programmable (from 0 to 120 s)

Pause time

0, 10, 20, 30, 60, 120 s

Closing leaf delay

0, 5, 10, 20 s

Opening leaf delay

2 s (Can be disabled with the dip-switch)

Thrust force

Dip-switch adjustable on 8 levels for each motor

Terminal board inputs

Open / Open free leaf / Stop / Limit-switch

Opening safety devices / Closing safety devices / Power Earth

Terminal board outputs

Flashing lamp - Motors - 24 Vdc accessories power

                                              supply- 24 Vdc indicator-light - Fail safe - 12 Vac electric

                                                       lock power supply

Rapid connector

Rapid connector 5 pins

Selectable functions

Logics and pause times - Thrust force -

Opening and closing leaf delay - Reversing stroke -
Fail safe - Closing safety devices logic - Pre-flashing

Programming key

Simple or Advanced work time learning,

with or without Limit-switch and/or encoder

For connection of

the photocells

and safety

devices, see

paragraph 4.1.

BLUE

BLUE

F

J2

Led

DL10

DS1

DS2

Led OP_A

TOTALLY OPEN LED

Led OP_B

LED: OPEN LEAF 1 / CLOSE

Led STOP

LED STOP

Led FSWCL

LED: CLOSING SAFETY DEVICES

Led FSWOP

LED: OPENING SAFETY DEVICES

Led FCA1

LED: LEAF 1 OPENING LIMIT-SWITCH

Led FCC1

LED: LEAF 1 CLOSING LIMIT-SWITCH

Led FCA2

LED: LEAF 2 OPENING LIMIT-SWITCH

Led FCC2

LED: LEAF 2 CLOSING LIMIT-SWITCH

DL10

LED: TIME LEARNING SIGNALLING

J1

LOW VOLTAGE TERMINAL BOARD

J2

RAPID CONNECTOR 5 PINS

J3

230 VAC POWER SUPPLY TERMINAL BOARD

J4

MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD

J5

INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BOARD

J6

LIMIT-SWITCH AND ENCODER TERMINAL BOARD

F1

MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A)

F2

LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)

F

TIME LEARNING SELECTION PUSH-BUTTON

DS1

1ST GROUP OF MICROSWITCH PROGRAMMING

DS2

2ND GROUP OF MICROSWITCH PROGRAMMING

Содержание JA388

Страница 1: ...JA388 CONTROL BOARD FOR 115V HINGED GATES EQUIPO ELECTR NICO PARA PORTONES DE TIPO BATIENTE 115V USE AND INSTALLATION INSTRUCTIONS INSTRUCCIONES PARA EL USO NORMAS DE INSTALACI N...

Страница 2: ...inflammablegasorfumesisaseriousdangertosafety 8 ThemechanicalpartsmustconformtotheprovisionsofStandardsEN12604 andEN12605 For non EU countries to obtain an adequate level of safety the Standards ment...

Страница 3: ...i automatic B Dead man C Stepped semi automatic Opening closing time Programmable from 0 to 120 s Pause time 0 10 20 30 60 120 s Closing leaf delay 0 5 10 20 s Opening leaf delay 2 s Can be disabled w...

Страница 4: ...6 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX CL TX CL 1 2 5 4 3 1 2 RX OP CL TX OP CL Fig 3 Opening closing safety devices they operate during the gate opening and clos...

Страница 5: ...Total Opening command N O any pulse generator push button detector etc which byclosingacontact commands opening and or closing of both gate leaves Toinstallseveralfullopeningpulsegenerators connect t...

Страница 6: ...this terminal and the 24V supply To avoid compromising correct operation of the system do not exceed the indicated power LOCK Terminal 21 Power supply to electric lock If required necessary connect a...

Страница 7: ...OFF OFF 5 6 ON ON OFF ON SW3 ON ON ON ON OFF OFF 7 OFF ON OFF 8 MAX OFF OFF OFF 1 2 3 4 5 6 7 8 9 10 11 12 1 MIN 2 3 4 SW4 ON OFF ON OFF SW5 ON ON OFF OFF 5 6 ON ON OFF ON SW6 ON ON ON ON OFF OFF 7 O...

Страница 8: ...h a STOP command 9 Release the operators close the leaves and re lock the operators 6 3 LEARNING OF OPERATING TIMES 6 3 2 LEARNINGWITHLIMIT SWITCHES Learning with limit switches can be done in two dif...

Страница 9: ...operation Notes The deceleration pulse should be supplied a little earlier with respect to the stop limit to prevent the leaf reaching it at full speed it would be taken for an obstacle If only one le...

Страница 10: ...s or leaf No effect No effect Closes the leaves or leaf Stops operation No effect OPEN B disabled No effect OPEN A disabled No effect PULSES No effect OPEN B disabled Stops operation OPEN B disabled S...

Страница 11: ...note notes note notas anmerkung...

Страница 12: ...note notes note notas anmerkung...

Страница 13: ...note notes note notas anmerkung...

Страница 14: ...note notes note notas anmerkung...

Страница 15: ...dor C Semiautom tica paso paso Tiempodeapertura cierre Programable de0a120s Tiempodepausa 0 10 20 30 60 120s Tiempoderetardodelahojaencierre 0 5 10 20s Tiempoderetardodelahojaen apertura 2s Puedeexclu...

Страница 16: ...sejado 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX CL TX CL 1 2 5 4 3 1 2 RX OP CL TX OP CL Fig 3 Dispositivos de seguridad en apertura cierre int...

Страница 17: ...contacto manda la apertura y o cierre de ambas hojas de la cancela Para instalar varios emisores de impulso de apertura total conecten los contactos N A en paralelo v ase fig 13 OPEN B Mando de Apertu...

Страница 18: ...sistema no hay que superar la potencia indicada LOCK Alimentaci n electrocerradura Conecten entre este borne y el 24V una eventual electrocerradura 12 V ac 4 6 Conector J2 Conector r pido 5 pins Se ut...

Страница 19: ...FF 1 2 3 4 5 6 7 8 9 10 11 12 1 MIN 2 3 4 SW4 ON OFF ON OFF SW5 ON ON OFF OFF 5 6 ON ON OFF ON SW6 ON ON ON ON OFF OFF 7 OFF ON OFF 8 MAX OFF OFF OFF E SW7 ON SW8 ON A A ON ON OFF ON SW9 ON OFF OFF A...

Страница 20: ...mpulso de Open que sustituye al fin de carrera Si s lo est presente una hoja hay que realizar igualmente toda la secuencia Cuando termina la apertura de la hoja hay que dar 5 impulsos de Open hasta qu...

Страница 21: ...cela est cerrada 2 Abran y mantengan abierto el contacto de Stop 3 Comprueben que el led DL10 est encendido si est apagado el predestello ya est inactivo 4 Presionen el pulsador F durante un instante...

Страница 22: ...bido Ning n efecto si ha de abrir inhibe OPEN Ning n efecto OPEN inhibido encendida Ning n efecto OPEN inhibido Tab 3 d Ning n efecto memoriza OPEN Ning n efecto OPEN A B inhibidos Abre las hojas o la...

Страница 23: ...ra evitar que la automaci n pueda ser accionada involuntariamente HINWEISE F R DEN INSTALLATIONSTECHNIKER ALLGEMEINE SICHERHEITSVORSCHRIFTEN 1 ACHTUNG Um die Sicherheit von Personen zu gew hrleisten s...

Страница 24: ...senziali di sicurezza delle seguenti direttive 73 23 CEE e successiva modifica 93 68 CEE 89 336 CEE e successiva modifica 92 31 CEE e 93 68 CEE Grassobbio 1Marzo2002 L Amministratore Delegato D Gianan...

Отзывы: