Genius GX2440 Скачать руководство пользователя страница 8

14

14

14

Step 9: 

Maintenance

Continuously monitors the battery to determine when 
a maintenance charge should be initiated. If the battery 
voltage falls below its target threshold, the charger will 
restart the Maintenance cycle until voltage reaches its 
optimal state and then discontinues the charge cycle. 
The cycle between Optimization and Maintenance is 
repeated indefinitely to keep the battery at full charge. 
The battery charger can be safely left connected 
indefinitely without the risk of overcharging.

Charging Steps.

Step 1 & 2: 

Analyze & Diagnose

Checks the battery’s initial condition, including voltage, 
state-of-charge and health, to determine if the battery is 
stable before charging.

Step 3:

 Recovery

Initializes the Recovery desulfation process (if needed) for 
deeply discharged or sulfated batteries by pulsing small 
amounts of current.

Step 4:

 Initialize

Starts the charging process with a gentle (soft) charge.

Step 5 & 6: 

Opportunity & Bulk

Begins with opportunity charging at a high current, then 
steps down to the Bulk charging process based on the 
condition of the battery and returns 80% of the battery’s 
capacity.

Step 7: 

Absorption

Brings the charge level to 90% by delivering small 
amounts of current to provide a safe, efficient charge. 
This limits battery gassing and is essential to prolonging 
battery life.

Step 8: 

Optimization

Finalizes the charging process and brings the battery to 

maximum capacity.  In this step, the charger utilizes multi-

layered charging profiles to fully recapture capacity and 

optimize the specific gravity of the battery for increased 

run time and performance. The charger will switch to 

Maintenance if the battery tells the charger that more 

current is needed.

Technical Specifications.

110-240 VAC, 50-60Hz

85-240 VAC, 50-60Hz

90% Approx.

960W Max

<5mA

-20°C to +50°C

-40°C to +70°C

9 Step, Smart Charger

Wet, Gel, MF, CA, EFB, 

AGM & LIB

55-425Ah, Maintains 

All Battery Sizes

IP66

Natural Convection

>0.96

12A @ 105VAC

30.4 x 21.6 x 10.3 cm

6kg (13.2lbs)

Input Voltage AC:

Working Voltage AC:

Efficiency:

Power:

Back Current Drain:

Operating Temperature:

Storage Temperature:

Charger Type:

Battery Chemistries:

Battery Capacity:

Housing Protection:

Cooling:

Power Factor Full Load:

Max. AC Current Full Load:

Dimensions:

Weight:

Содержание GX2440

Страница 1: ...OCO for personalized support not available in all areas visit www no co connect What s In The Box GX Series Smart Charger AC Cable User Guide Information Guide and Warranty User Guide GXSeries PRIOR TO USE READ AND UNDERSTAND PRODUCT SAFETY INFORMATION Failure to follow the instructions may result in ELECTRICAL SHOCK EXPLOSION or FIRE which may result in SERIOUS INJURY DEATH DAMAGE TO DEVICE or PR...

Страница 2: ...he mounting surface It is important to keep in mind the distance to the battery Allow for 12 inches 304mm of slack in cables between connections Charging Modes The GX Series Chargers have seven 7 modes Standby NORM COLD AGM AGM LI ION REPAIR and SUPPLY Some charge modes must be pressed and held for three 3 seconds to enter the mode These Press and Hold modes are advanced charging modes that requir...

Страница 3: ... never given the opportunity to receive a full charge The most common battery problems are battery sulfation and stratification Both battery sulfation and stratification will artificially raise the open circuit voltage of the battery causing the battery to appear fully charged while providing low capacity Use Repair in attempt to reverse these problems For optimal results take the battery through ...

Страница 4: ...ES TO MINIMIZE RISKS TO ELECTRONICS DISCONNECT THE BATTERY BEFORE USING THIS MODE Using Supply Press Hold Supply converts the charger to a constant current constant voltage DC power supply To enter Supply Mode the charger must not be connected to the battery CAUTION THIS MODE IS FOR LEAD ACID BATTERIES ONLY PRIOR TO USE READ YOUR DEVICE MANUAL TO DETERMINE IF IT IS SUITABLE FOR USE WITH THIS MODE ...

Страница 5: ...tive POS P battery terminal 2 Connect the negative black battery clamp or eyelet terminal connector to the negative NEG N battery terminal or vehicle chassis 3 Connect the battery charger s AC power plug into a suitable electrical outlet Do not face the battery when making this connection 4 When disconnecting the battery charger disconnect in the reverse sequence removing the negative first or pos...

Страница 6: ...itions are displayed with the Error LED and Standby LED flashing back and forth The number of flashes between each pulse denotes a potential Error Condition except reverse polarity and low voltage battery Error Reason Solution Single Flash Battery will not hold a charge Have battery checked by a professional Possible battery short Have battery checked by a professional Battery voltage is too high ...

Страница 7: ...s in applications where charging is intermittent between use Memory Returns to last selected mode when restarted Interactive Alters the charging process based on organic battery feedback Recovery Applies a high voltage pulse charge when low voltage sulfation or lost capacity is detected Safe Protects against reverse polarity sparks overcharging overcurrent open circuits short circuits and overheat...

Страница 8: ... the Bulk charging process based on the condition of the battery and returns 80 of the battery s capacity Step 7 Absorption Brings the charge level to 90 by delivering small amounts of current to provide a safe efficient charge This limits battery gassing and is essential to prolonging battery life Step 8 Optimization Finalizes the charging process and brings the battery to maximum capacity In thi...

Страница 9: ...GXS021716A no co 1 800 456 6626 support no co 30339 Diamond Parkway 102 Glenwillow OH 44139 United States of America ...

Отзывы: