DC Output Connection Port
The DC Out Connection Port requires positive (red),
and negative (black) connections. 10AWG minimum
wire gauge is required. Make sure all connections are
securely tightened and insulated from each other before
operation. To increase the charger’s waterproofing,
completely seal the entire connection with electric
sealant.
Inhibit Port (Optional For Operation)
The Inhibit Port contains a Relay rated at 20A. When
the Charger has AC power, the relay will close allowing
current flow. When the charger is removed from AC
power, it takes approximately 15 seconds for the
capacitors to discharge and the relay to open.
Remote LEDs Port (Optional For Operation)
The Remote LEDs Port can be used to connect LEDs
for easy monitoring when the charger’s LEDs are not
accessible. The port supports two LEDs, reversing
polarity to change from “Charging” to “Charged.”
take up to four (4) hours to complete the recovery process
and will return to Standby when completed.
CAUTION.
USE THIS MODE WITH CARE. THIS MODE
IS FOR LEAD-ACID BATTERIES ONLY. THIS MODE USES
A HIGH CHARGING VOLTAGE AND MAY CAUSE SOME
WATER LOSS IN WET (FLOODED) CELL BATTERIES. BE
ADVISED, SOME BATTERIES AND ELECTRONICS MAY BE
SENSITIVE TO HIGH CHARGING VOLTAGES. TO MINIMIZE
RISKS TO ELECTRONICS, DISCONNECT THE BATTERY
BEFORE USING THIS MODE.
Using Supply. [Press & Hold]
Supply converts the charger to a constant current, constant
voltage DC power supply. To enter Supply Mode, the
charger must not be connected to the battery.
CAUTION.
THIS MODE IS FOR LEAD-ACID BATTERIES
ONLY. PRIOR TO USE, READ YOUR DEVICE MANUAL
TO DETERMINE IF IT IS SUITABLE FOR USE WITH THIS
MODE. BOTH THE SPARK PROOF AND REVERSE
POLARITY SAFETY FEATURES ARE DISABLED IN THIS
MODE. DO NOT ALLOW THE POSITIVE AND NEGATIVE
BATTERY CLAMP OR EYELET TERMINAL CONNECTORS
TO TOUCH OR CONNECT TO EACH OTHER AS THE
CHARGER COULD GENERATE SPARKS. CHECK THE
POLARITY OF THE BATTERY TERMINALS BEFORE USING
THIS MODE.
Cable Connections
The GX Series Chargers have AC and DC connection
ports that are designed to allow the user to choose custom
cables to fit the desired application. Both the AC and DC
connection ports are labeled to inform the user the proper
way to install custom cables.
AC Input Connection Port
The AC Input Connection Port requires line (black), return
(white) and ground (green) connections. The unit must
be grounded for safe operation. 16AWG minimum wire
gauge is required. Make sure all connections are securely
tightened and insulated from each other before operation.
To increase the charger’s waterproofing, completely seal the
entire connection with electric sealant.
AC Input Connection Port