2

22

Basic Charging Modes 

Voltage and current depend on model of charger. 

Specifications for each model are listed below.

CAUTION: 

ALWAYS VERIFY THE VOLTAGE OF A BATTERY 

SYSTEM BEFORE ATTEMPTING TO CHARGE. 

ONLY USE THE GX SERIES CHARGER THAT IS 

DESIGNED FOR THE SAME VOLTAGE AS YOUR 

BATTERY SYSTEM. 

Contacting NOCO.

About GX Series Chargers.

 The NOCO Genius

®

 GX 

Series of chargers represents some of the most innovative 

and advanced technology on the market, making each 

charge simple and easy. The GX is designed for charging all 

types of 24V, 36V or 48V lead-acid and lithium-ion battery 

systems, including Wet (Flooded), Gel, MF (Maintenance-

Free), CA (Calcium), EFB (Enhanced Flooded Battery), AGM 

(Absorption Glass Mat), and LIB (Lithium Ion) batteries. It 

is suitable for charging battery capacities from 25 to 500 

Amp-Hours and maintaining all battery sizes.

Getting Started.

 Before using the charger, carefully 

read the battery manufacturer’s specific precautions and 

recommended rates of charge for the battery. Make sure 

to determine the voltage and chemistry of the battery by 

referring to your battery owner’s manual prior to charging.

Mounting.

 The GX Series Chargers have four (4) external 

holes for mounting. Make sure there are no obstructions 

behind the mounting surface. It is important to keep in mind 

the distance to the battery. Allow for 12-inches (304mm) of 

slack in cables between connections.

Charging Modes.

 The GX Series Chargers have seven 

(7) modes: Standby, NORM, COLD/AGM, AGM+, LI-ION, 

REPAIR and SUPPLY.  Some charge modes must be 

pressed and held for three (3) seconds to enter the mode. 

These “Press and Hold” modes are advanced charging 

modes that require your full attention before selecting. It 

is important to understand the differences and purpose 

of each charge mode. Do not operate the charger until 

you confirm the appropriate charge mode for your battery. 

Below is a brief description:

1.800.456.6626
[email protected]
30339 Diamond Parkway, #102
Glenwillow, OH 44139
United States of America

Phone:

Email:

Mailing Address:

Mode

Explanation

NORM

Standby

COLD/

AGM

No Power

28.8V ± 0.3V  |  40A ± 1A
43.2 +/- 0.45V  |  26A ± 1A
57.6V +/- 0.6V |  20A ± 1A

29.4V ± 0.3V  |  40A ± 1A
44.1V +/-0.45V |  26A ± 1A
58.8V  +/-0.6V  |  20A ± 1A

GX2440
GX3626
GX4820

GX2440
GX3626
GX4820

In Standby mode, the charger is not 

charging or providing any power to 

the battery. Energy Save is activated 

during this mode, drawing microscopic 

power from the electrical outlet. When 

selected, an orange LED will illuminate. 

For charging Wet Cell, Gel Cell, 

Enhanced Flooded, Maintenance-Free 

and Calcium batteries. When selected, 

a white LED will illuminate. 

For charging batteries in cold 

temperatures below 50ºF (10ºC) or 

AGM batteries. When selected, a blue 

LED will illuminate.

Содержание GX2440

Страница 1: ...OCO for personalized support not available in all areas visit www no co connect What s In The Box GX Series Smart Charger AC Cable User Guide Information Guide and Warranty User Guide GXSeries PRIOR TO USE READ AND UNDERSTAND PRODUCT SAFETY INFORMATION Failure to follow the instructions may result in ELECTRICAL SHOCK EXPLOSION or FIRE which may result in SERIOUS INJURY DEATH DAMAGE TO DEVICE or PR...

Страница 2: ...he mounting surface It is important to keep in mind the distance to the battery Allow for 12 inches 304mm of slack in cables between connections Charging Modes The GX Series Chargers have seven 7 modes Standby NORM COLD AGM AGM LI ION REPAIR and SUPPLY Some charge modes must be pressed and held for three 3 seconds to enter the mode These Press and Hold modes are advanced charging modes that requir...

Страница 3: ... never given the opportunity to receive a full charge The most common battery problems are battery sulfation and stratification Both battery sulfation and stratification will artificially raise the open circuit voltage of the battery causing the battery to appear fully charged while providing low capacity Use Repair in attempt to reverse these problems For optimal results take the battery through ...

Страница 4: ...ES TO MINIMIZE RISKS TO ELECTRONICS DISCONNECT THE BATTERY BEFORE USING THIS MODE Using Supply Press Hold Supply converts the charger to a constant current constant voltage DC power supply To enter Supply Mode the charger must not be connected to the battery CAUTION THIS MODE IS FOR LEAD ACID BATTERIES ONLY PRIOR TO USE READ YOUR DEVICE MANUAL TO DETERMINE IF IT IS SUITABLE FOR USE WITH THIS MODE ...

Страница 5: ...tive POS P battery terminal 2 Connect the negative black battery clamp or eyelet terminal connector to the negative NEG N battery terminal or vehicle chassis 3 Connect the battery charger s AC power plug into a suitable electrical outlet Do not face the battery when making this connection 4 When disconnecting the battery charger disconnect in the reverse sequence removing the negative first or pos...

Страница 6: ...itions are displayed with the Error LED and Standby LED flashing back and forth The number of flashes between each pulse denotes a potential Error Condition except reverse polarity and low voltage battery Error Reason Solution Single Flash Battery will not hold a charge Have battery checked by a professional Possible battery short Have battery checked by a professional Battery voltage is too high ...

Страница 7: ...s in applications where charging is intermittent between use Memory Returns to last selected mode when restarted Interactive Alters the charging process based on organic battery feedback Recovery Applies a high voltage pulse charge when low voltage sulfation or lost capacity is detected Safe Protects against reverse polarity sparks overcharging overcurrent open circuits short circuits and overheat...

Страница 8: ... the Bulk charging process based on the condition of the battery and returns 80 of the battery s capacity Step 7 Absorption Brings the charge level to 90 by delivering small amounts of current to provide a safe efficient charge This limits battery gassing and is essential to prolonging battery life Step 8 Optimization Finalizes the charging process and brings the battery to maximum capacity In thi...

Страница 9: ...GXS021716A no co 1 800 456 6626 support no co 30339 Diamond Parkway 102 Glenwillow OH 44139 United States of America ...

Отзывы: