1.
These parameters are used to link a bin number to each feed auger. These
parameters vary from 0 to 9999.
2.
These parameters are used to select each feed auger inputs for a program.
These inputs are to determine if the feed augers are active or not. These
parameters vary from 1 to 8 (up to 16 with an 8 inputs board) and
"–-"
when
no input is selected.
3.
These parameters are used to select the feed auger outputs for a program.
When a feed auger has an activation request, the selected relay will be
activated. These settings vary from 1 to 12 and
"–-"
when no output is
selected.
4.
These parameters show the presence of conflict between a feed auger and
an actuator using the same relay. In case of conflict, the actuator has priority
and the feed auger demand has no impact on the relay. An X is showed
when there is a conflict and nothing in absence of conflict
F e e d A u g e r P r o g #
N u m b e r s
A u g 1 ( 0 0 0 0 ) A u g 5 ( 0 0 0 0 )
A u g 2 ( 0 0 0 0 ) A u g 6 ( 0 0 0 0 )
A u g 3 ( 0 0 0 0 ) A u g 7 ( 0 0 0 0 )
A u g 4 ( 0 0 0 0 ) A u g 8 ( 0 0 0 0 )
I n p u t s O u t p u t s
A u g . 1 : - - - - X
A u g . 2 : - - - - X
A u g . 3 : - - - - X
A u g . 4 : - - - - x
A u g . 5 : - - - - x
A u g . 6 : - - - - x
A u g . 7 : - - - - x
A u g . 8 : - - - - x
[1]
[1]
[2]
[3]
[4]
Содержание GE-NUTRI
Страница 3: ...GE NUTRI WIRING DIAGRAM GE NUTRI Section A 3 WIRING DIAGRAM GE NUTRI SECTION A...
Страница 10: ...GE NUTRI INSTALLATION Section B 10 GE NUTRI INSTALLATION GE NUTRI SECTION B...
Страница 21: ...GE NUTRI USER S GUIDE GE NUTRI Section C 21 USER S GUIDE GE NUTRI SECTION C...
Страница 71: ...GE NUTRI INDEX WARRANTY GE NUTRI Section D 71 INDEX WARRANTY GE NUTRI SECTION D...
Страница 75: ......
Страница 76: ...GE NUTRI VER 1 9 2 September 2020...