BRAIN 17
25
732788 - Rev. A_1
ENGLISH
Display
Advanced Function
Default
PF
PRE-FLASHING:
You can enable/disable the pre-flashing. Pre-flashing duration = 3 sec.
Y
= enabled before each movement
no
= disabled
no
EC
ANTI-CRUSHING SENSITIVITY (visualised only with the function
En
=
Y
):
Varying this function varies the amount of time after which, in case of obsta-
cle, the board commands reversal of the leaves, or it will command a stop
if the leaves are in the contact point search space (see the parameter
rB
).
The fourth consecutive obstacle detected in the same direction and position
will be defined as a contact point and the leaf will stop in that position.
00
= minimum sensitivity (maximum time before reversal)
10
= maximum sensitivity (minimum time before reversal)
05
r8
MECHANICAL STOP SEARCH ANGLE (displayed only if function
En
=
Y
and functions
Fc
and
FA
=
no
or =
02
):
You can adjust the contact point search angle within which the board will stop
movement without reversing, if it encounters an obstacle or the contact point.
Adjustable in two modes:
01
= Low contact point search space (about 1 degree)
02
= High contact point search space (about 4 degree)
02
SP
OUTPUT WL:
You can set the output W.L. (open collector N.O.) in one of the following
functions:
00
= INDICATOR LIGHT (OFF = closed, ON = during opening and open/
pause, FLASHING = during closing)
01
= COURTESY LIGHT (fixed time 90 seconds)
00
Содержание Brain 17
Страница 1: ...BRAIN 17 BRAIN 17...