1.4 Specification

Camera

Image Sensor

1 / 2.9” 6MP progressive scan CMOS

Image Size

2160 × 2160

Electronic Shutter

1 / 25 s ~ 1 / 100000 s

Minimum Illumination

0.068 Lux @ F2.0, AGC ON, 0 Lux with IR

Lens

1.07mm @ F2.5 Horizontal field of view, 180° Wall mount, 360° Ceiling 

mount

Day & Night

ICR

Wide Dynamic Range

Digital WDR

BLC

Yes

HLC

Yes

Digital NR

3D DNR

Slow Shutter

Yes

Image

Video Compression

H.265 / H.264 / MJPEG

Encoding Type

VBR (Five levels adjustable) / CBR

Main Stream

Fisheye Pa3 PTZ 

50Hz: 25fps @ (2160 × 2160 / 1920 × 1920 / 1440 × 1440), 25fps @(1920 

× 1080), 25fps @ (960 × 540)*3 

60Hz: 30fps @ (2160 × 2160 / 1920 × 1920 / 1440 × 1440), 30fps @ (1920 

× 1080), 30fps @ (960× 540)*3

4 PTZ

50Hz: 25fps @ (2160 × 2160 / 1920 × 1920 / 1440 × 1440),

25fps @ (960 × 540)*4 

60Hz: 30fps @ (2160 × 2160 / 1920 ×

1920 / 1440 × 1440), 30fps @ (960 × 540)*4

Bit Rate

128 Kbps ~ 16 Mbps

Audio Compression

G711A / U

Audio Bit Rate

8Kbps ~ 48 Kbps

Image Settings

ROI, Saturation, Brightness, Chroma, Contrast, Wide Dynamic, Sharpen, 

NR,etc. Adjustable through client software or web browser

ROI

Each ROI to be configured separately

Functions

Remote Monitoring

Web browsing, CMS remote control

Online Connection

Supports simultaneous monitoring for up to 11 users, supports multi-

stream real time transmission

Network Protocol

UDP, Pv4, IPv6, DHCP, NTP, RTSP, PPPoE, DDNS, SMTP, FTP, SNMP, UPnP, 

HTTP

Interface Protocol

Onvif compatible

Storage

Network remote storage, micro SD card storage

Smart Alarm

Motion detection, sensor alarm

General Function

Watermark, IP address filtering, video mask

PoE

Yes

IR Distance

20 ~ 30 m

Interface

Network

RJ45

Video Output

No

Audio

Built-in MIC x1

Storage

Built-in Micro SD card slot, Up to 128GB

Hardware Reset

Yes

Others

Ingress Protection

IP67

Power Supply

DC12V / PoE

Power Consumption

< 12W

Operating Environment

- 30 °C ~ 50°C (-22°F~122°F) 

Humidity: Less than 95% (Non-condensing)

Dimensions

130 × 41 mm

Weight

Approximately 0.45Kg

Содержание WIP6F

Страница 1: ...Quick Start Guide Please read these instructions carefully before operating the unit and keep for further reference 6MP IP IR Fisheye Camera WIP6F...

Страница 2: ...electrical safety regulations of the nation and region When the product is mounted on wall or ceiling the device needs to be firmly fixed Make sure the power supply voltage is correct before using th...

Страница 3: ...oduct Features 4 1 2 Product Dimensions 4 1 3 Contents 4 1 4 Specification 5 2 0 Overview 6 3 0 Installation 8 3 1 Installing the Camera 8 3 2 Installing the Camera with a Junction Box 9 3 3 Installin...

Страница 4: ...distance 3D DNR digital WDR HLC BLC and ROI coding 1x CVBS output 1CH audio input 1CH audio output 1CH built in MIC Built in micro SD card slot up to 128GB Hardware reset RS485 1CH alarm input 1CH al...

Страница 5: ...Compression G711A U Audio Bit Rate 8Kbps 48 Kbps Image Settings ROI Saturation Brightness Chroma Contrast Wide Dynamic Sharpen NR etc Adjustable through client software or web browser ROI Each ROI to...

Страница 6: ...and then connect the signal cable of the sensor to the alarm input port ALM INA of the camera Alarm Output Loosen the screws in the alarm output port Then insert the signal wires of the alarm output...

Страница 7: ...the nut from the main element 2 Run the network cable without RJ 45 connector through both elements Then crimp the cable with RJ 45 connector 3 Connect the cable to the hermetic connector Then tighte...

Страница 8: ...ent and place the cover of the camera within 4 hours of removing it 1 Remove the fixed ring from the gap of the camera see Installing SD Card 2 Drill the screw holes and cut the cable hole A in the ce...

Страница 9: ...rom the gap of the camera see Installing SD Card 2 Install the junction box onto the wall 3 Route the cables through the cable hole take side conduit cabling for example and connect the cables Then fi...

Страница 10: ...IP IR Fisheye Camera 10 3 3 Installing SD Card 1 Remove the fixed ring from the gap of the camera 2 Loosen the screws of the cover of the SD card and then insert the SD card After that install the cov...

Страница 11: ...shown below 3 Modify the IP address The default IP address of this camera is 192 168 226 201 Click the information of the camera listed in the above table to show the network information on the right...

Страница 12: ...fault password is 123456 Access the Web Browser 1 Make sure that the camera and the PC are connected via LAN 2 Find the IP Tool from the CD and then install it in the computer After that run the IP To...

Страница 13: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk...

Отзывы: