Operator's Manual
Second Edition • Third Printing
Operating Instructions
58
SX-150 • SX-180
Part No. 1262335
Platform Out of Level (P22 code)
Bypass key position to be used to level the
platform if ground control display shows platform
out of level (P22) and platform level controls do not
work.
To operate:
1
Turn the engine off.
2
Turn the main key switch to ground control.
Remove the key from the main key switch and
insert the key into the bypass/recovery key
switch.
3
Turn the
bypass/recovery key
switch to the bypass
position.
4
Using emergency power, operate the platform
level button to level the platform.
5
Turn the bypass/recovery key switch to the run
position.
6
Remove the key from the bypass/recovery key
switch and insert the key into the main key
switch.
7
Push in and then pull out the red Emergency
Stop button.
8
If the P22 code is still visible, tag and remove
the machine from service until the fault has
been corrected by a qualified service
technician.
Platform Out of Level
(Platform Level > 15 Degrees Fault)
If ground control display shows PLATFORM
LEVEL > 15 DEGREES FAULT and the platform
level controls do not work, the machine will need to
be recovered by trained and authorized personnel
or a qualified service technician.
Generator
To operate the generator, move the generator
toggle switch.
Note: If the foot switch is activated during
generator start-up, the generator will not operate.
The generator indicator light will flash during
generator start-up. After generator start-up is
complete, the generator indicator light will stay lit
and the engine rpm will move into high rpm, rabbit
symbol mode.
Note: Only jib and platform functions are operable
during generator operation. The foot switch must
be pressed to enable the jib and platform functions.
The generator will continue to function during jib
and platform operation. To operate the drive,
turntable and boom functions the generator must
be turned off.
Plug a power tool into the power to platform GFCI
outlet. There is GFCI protection built into the
generator electrical box, located on the turntable
chassis.
To turn off the generator, move the generator
toggle switch. The generator indicator light will
flash during generator shut-down sequence. After
the generator shut-down sequence is complete the
generator indicator light will turn off and the engine
rpm will move into low rpm, turtle symbol mode.
P22
P22
Содержание SX-150
Страница 9: ...Second Edition Third Printing Operator s Manual General Safety Part No 1262335 SX 150 SX 180 7 ...
Страница 10: ...Operator s Manual Second Edition Third Printing General Safety 8 SX 150 SX 180 Part No 1262335 ...
Страница 11: ...Second Edition Third Printing Operator s Manual General Safety Part No 1262335 SX 150 SX 180 9 ...
Страница 12: ...Operator s Manual Second Edition Third Printing General Safety 10 SX 150 SX 180 Part No 1262335 ...
Страница 13: ...Second Edition Third Printing Operator s Manual General Safety Part No 1262335 SX 150 SX 180 11 ...
Страница 29: ...Second Edition Third Printing Operator s Manual Controls Part No 1262335 SX 150 SX 180 27 ...
Страница 49: ...Second Edition Third Printing Operator s Manual Inspections Part No 1262335 SX 150 SX 180 47 ...
Страница 51: ...Second Edition Third Printing Operator s Manual Inspections Part No 1262335 SX 150 SX 180 49 ...
Страница 77: ......