20
Genie Runabout
Part No. 72129
Operator's Manual
First Edition • Sixth Printing
Test the Platform Extension Limit Switch
(if equipped)
Note: This test is only required on GR-15 models
with an optional platform extension.
Note: Some GR-15 models are equipped to drive at
up to 12 feet / 3.6 m with the platform extended.
These models have a limit switch on the back of
the platform next to the mast. Before performing
this test, determine if your machine is equipped
with this limit switch.
Models with limit switch: Perform
this test with the platform raised
approximately 13 feet / 3.9 m.
Models without limit switch:
Perform this test with the platform
fully lowered.
48 Move the lift/drive select switch to the lift
position.
49 Fully lower the platform OR raise the platform to
approximately 13 feet / 3.9 m.
50 Step on the platform extension release pedal
and extend the platform.
51 Move the lift/drive select switch to the drive
position.
52 Slowly move the control handle to the full drive
position.
Result: The drive function should not operate.
FUNCTION TESTS