background image

7

©2011 The Genie Company 

9/2011

 

 

IntelliCode® 1 or 2 wireless keypad

Door moves.

 

   

 

(To verify memory is cleared—try to operate the garage door 
using one of your remote devices. The opener should 
not respond.)

Both LEDs OFF confirms communication  
is established with operator.

Round LED BLUE then OFF, Long LED FLASHING

PROGRAM

SET

 

 

Press & hold 
2 seconds.
Release.

ACTION    

                     LED INDICATION/RESULT

BLUE

OFF

OFF

OFF

OFF

OFF

BOTH BLUE 

FLASHING

Release.

OFF

PURPLE 

FLASHING

Clearing remotes from powerhead memory will 
clear ALL programmed remotes and wireless 
keypad.

NOTE:

All remotes and wireless keypads 
must be reprogrammed.

Your door opener will no longer recognize any 
signal received from a missing remote.

Press & hold
BOTH open 
and close 
buttons 
together.

REMOTE CLEARED FOR REPROGRAMMING

LOST OR STOLEN REMOTE - CLEARING MEMORY

   

 

OPTIONAL PROGRAMMING

1

2

3

Enter your PIN 
on the wireless keypad.

OFF

BLUE

OFF

 

Press & release 2 times.

Press & 
release

ACTION    

                         LED INDICATION/RESULT

Genie® Intellicode® 2 Wireless Keypad

 comes 

with a complete set of instructions.

Independent Light Control Button

Controls door opener lights from inside garage

Sure-Lock™ Button

 

 

 

r

e

t

f

a

 

s

l

o

r

t

n

o

c

 

s

e

l

b

a

s

i

d

 

K

C

O

L

 

 

 .

d

e

s

o

l

c

 

y

l

e

t

e

l

p

m

o

c

 

s

r

o

o

d

 
 – UNLOCK allows controls to  
 work 

normally

Indicator Light

Red indicator light is always ON

When Sure-Lock™ is ON the 
indicator light flashes

Open/Close Button

Open and closes door from inside garage.

WALL CONSOLE - OVERVIEW

Use only the Series III wall console provided with this unit.
Wall console has three buttons and one indicator light. 

Indicator Light

Indicator light will display Red when wall console is 
properly wired and Sure-Lock

 is OFF.  When Sure

 is ON indica

Lock

 

tor light flashes.

Open/Close Button

Use this button to open or close garage door.  When 
Sure-Lock™ is ON the Open/Close button will CLOSE 
door only.  

Note:

 Constant button pressure in the 

CLOSE mode will override error responses in the 
powerhead and close door. 

Independent Light Control Button

Use this button to turn powerhead lights ON.  
Powerhead lighting will remain ON until this button 
is pressed again or a door action has been completed.  

Note

: If opener has a Motion Detector sensor, it will  

keep powerhead lights ON as long as motion is detected 

Sure-Lock™ Button

When Sure-Lock™ is ON the powerhead cannot be 
activated by the wall console or a remote.

s

  Press and hold for 5 seconds (or until Indicator 

Light flashes) to activate Sure-Lock™.

s

  Press and release to turn Sure-Lock™ OFF. 

Tip: 

         If the Wall Console is energized (LED ON), but the 
door does not 
respond to the 
OPEN/CLOSE 
button-verify
the Console is 
wired to the 
BWC terminals
on the powerhead.

STB

BWC

IWC

NOT

USED

NOT

USED

NOT

USED

NOT

USED

FROM STBs

FROM WALL

CONSOLE

STB

BWC

IWC

FROM STBs

FROM WALL

This opener has a Serial Number sticker in which the serial 
numbers begin with 10 or higher.  

MODEL AC SR3

THE GENIE COMPANY

FCC ID: B8Q AC SR3

Residential Door Operator

IC:  2133A-CSD1D

120V. 60HZ. 5A

FOR H LP CAL  1-800-35GENIE OR WWW.GENIECOMPANY.COM

S/N:10XXXX XXXXXXX

Wall consoles from other manufacturers may not work with 
openers of these serial number groups.  Genie® Series I wall 
buttons and Series II wall consoles will not work with openers 
of this serial number group.

ROGRAM

SET

 

Press & Hold  for 
2 seconds or until 
round LED turns blue 
then OFF. 
Then Long LED flashes purple.

1

2

4

5

PURPLE

FLASHING

CONSOLE

Содержание IntelliG 1000

Страница 1: ...nly with a one piece or sectional door SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER CHAIN BELT GARAGE DOOR OPENER MODELS IntelliG 1000 1200 SilentMax 1000 1200 Chai...

Страница 2: ...THIS PAGE LEFT BLANK...

Страница 3: ...NOTE is used to indicate important steps to be followed or important considerations Do NOT allow children to play with Door Opener Keep people clear of opening while door is moving Do NOT operate a d...

Страница 4: ...Wall Console Series III Operates door opener from inside garage The Wall Console has an Indicator Light with Open Close Sure Lock and Independent Light Control buttons 2011 The Genie Company 9 2011 r...

Страница 5: ...iew theAssembly Installation Poster to ensure all steps have been performed There are no assembly or installation steps included in this manual Contact your Genie Professional Dealer for an installati...

Страница 6: ...amming Remotes or it does not reverse it may be due to an improperly set down limit Repeat TRAVEL LIMITS program and Test again Repeat as needed until door passes test For further help refer to Mainte...

Страница 7: ...aration between the opener and receiver s Connect the opener into an outlet on a circuit different from that to which the receiver is connected s Consult your local dealer PROGRAM SET DOOR MOVES DOOR...

Страница 8: ...tor light will display Red when wall console is properly wired and Sure Lock is OFF When Sure is ON indica Lock tor light flashes Open Close Button Use this button to open or close garage door When Su...

Страница 9: ...he moving door in sight and away from people and objects until the door is completely closed NO ONE R O O D G N I V O M E H T F O H T A P E H T S S O R C D L U O H S 4 NEVER GO UNDER A STOPPED PARTIAL...

Страница 10: ...autions s Disconnect power from opener and disconnect carriage in rail from bullet before beginning this task Visually inspect the chain or belt every 6 months NOTE Tension adjustments should be made...

Страница 11: ...ntil you reach desired setting FORCE SETTINGS DONE PROGRAM SET Press Release PROGRAM SET FORCE ADJUSTMENT 1 2 3 4 5 USE CHART BELOW Press either until you reach the desired setting USE CHART BELOW LOC...

Страница 12: ...removing cover 1 2 3 4 5 6 1 2 3 7 6 POWER CORD CONNECTOR WHITE BLACK GREEN WHITE WHITE BLACK RED BLACK STRIPED WHITE WALL CONSOLE SCREW DRIVE MOTOR STRIPED WHITE SAFE T BEAM 5 4 3 2 1 Purchased Sepa...

Страница 13: ...l console button until door is completely closed s Check for interference from adjacent Safe T Beam units s ContactThe Genie Company at 1 800 35 GENIE Door starts down then STOPS before it is closed O...

Страница 14: ...WUDQVIHUDEOH RU DVVLJQDEOH 7KLV ZDUUDQW DSSOLHV RQO WR 3URGXFW LQVWDOOHG LQ D UHVLGHQWLDO RU RWKHU QRQ FRPPHUFLDO DSSOLFDWLRQ W GRHV QRW FRYHU DQ 3URGXFW LQVWDOOHG LQ FRPPHUFLDO RU LQGXVWULDO EXLOGLQJ...

Отзывы: