background image

 

 

©2011 The Genie Company

9/2011

5

WARNING

s

 Make sure doorway is in view and clear of obstacles and 

people to avoid injury or damage to property.

s

 DO NOT operate this unit from wall console before LIMITS 

and FORCE are set.  Severe damage to the opener can occur. 

s

 The bullet MUST be engaged to carriage BEFORE setting  

limits.  See Installation Poster (if provided) or call 
Customer Service at 800-35-GENIE or visit 
www.geniecompany.com.

NOTE: If bullet has NOT been engaged to 
the carriage, do so no .

PROGR

2

Please note that there is a 

30 second timeout

 between 

 each programming step.

If you see 

two flashing RED LEDs

, you have initiated 

a timeout.
In the ev

w  See page 9.

CONTACT REVERSE TEST

 

The Force and Limit settings MUST be COMPLETED 

before performing Contact Reverse Test.

1.

 

Test.

 

Place a 2" x 4" 
board (laid flat) 
under center of 
door opening.

 

2. Adjustment, if needed.

s

 If the door 

stops before it contacts the board

 

WARNING

 

A moving door can cause serious injury or death.

1.

   Keep people clear of opening while door is moving.

2. 

 Do 

NOT

 allow children to play with opener, including 

wall console, remote, or wireless keypad.

3. 

  During programming, door opener could begin to run, 

so stay away from moving door and its parts.

 

Once the Contact Revese Test is complete, 
continue with programming Remotes.

or it 

does not reverse, 

it may be due to an improperly set 

down limit. Repeat TRAVEL LIMITS program and 

Test again.

Repeat as needed until door passes test. For further help 
refer to Maintenance &Troubleshooting, page 13.
   

ent of a timeout you must restart at beginning. 

Press & hold 
2 seconds or until 
LEDs react. Release.

Press & hold 
2 seconds or until 
LEDs react. Release.

Long LED turns Blue, 
Round LED OFF.

Then Long LED OFF
Round LED Flashing.

Long LED turns Blue, then flashes.

Press & hold
until door  is fully 
open. Then release.

Press & 
Release.

DOOR LIMITS ARE SET

SET FORCE NEXT

PROGRAM

SET

 

FLASHING

DOOR FULLY OPEN

DOOR FULLY CLOSED

OFF

O

RED

RED

FF

Press & 
Release.

PROGRAM

SET

 

Press & 
Release the
Open/Close 
button.

DOOR CLOSES.

s

  When door contacts board, 

   it must stop and reverse direction 
   (within 2 seconds) to the fully 
   open position.

OFF

OFF

AMMING LIMITS 

TRAVEL LIMITS

UP LIMIT

DOWN LIMIT

Door fully closes.

Door fully opens.

FORCE CONTROL

Press & 
Release
Open/Close 
button.

ACTION    

           INDICATION/RESULT

ACTION    

           INDICATION/RESULT

Press & 
Release
Open/Close 
button.

ON WALL CONSOLE

 

Press & 
Release the
Open/Close 
button.

FORCE CONTROL IS SET

1

2

1

2

1

3

4

5

6

2

3

DOOR OPENS.

ACTION    

                         LED INDICATION/RESULT

OFF

OFF

ON

BLUE 

BOTH FLASH BLUE

FLASHING

Press & hold
until door  is fully 
closed. Then release.

B

During the initial setting 
of the limits- the LEDs will 
turn to RED—NOT OFF

oth BLUE then LEDs Off confirms limit set.

OFF

OFF

BOTH FLASH BLUE

Both BLUE then LEDs Off confirms limit set.

Содержание IntelliG 1000

Страница 1: ...nly with a one piece or sectional door SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER CHAIN BELT GARAGE DOOR OPENER MODELS IntelliG 1000 1200 SilentMax 1000 1200 Chai...

Страница 2: ...THIS PAGE LEFT BLANK...

Страница 3: ...NOTE is used to indicate important steps to be followed or important considerations Do NOT allow children to play with Door Opener Keep people clear of opening while door is moving Do NOT operate a d...

Страница 4: ...Wall Console Series III Operates door opener from inside garage The Wall Console has an Indicator Light with Open Close Sure Lock and Independent Light Control buttons 2011 The Genie Company 9 2011 r...

Страница 5: ...iew theAssembly Installation Poster to ensure all steps have been performed There are no assembly or installation steps included in this manual Contact your Genie Professional Dealer for an installati...

Страница 6: ...amming Remotes or it does not reverse it may be due to an improperly set down limit Repeat TRAVEL LIMITS program and Test again Repeat as needed until door passes test For further help refer to Mainte...

Страница 7: ...aration between the opener and receiver s Connect the opener into an outlet on a circuit different from that to which the receiver is connected s Consult your local dealer PROGRAM SET DOOR MOVES DOOR...

Страница 8: ...tor light will display Red when wall console is properly wired and Sure Lock is OFF When Sure is ON indica Lock tor light flashes Open Close Button Use this button to open or close garage door When Su...

Страница 9: ...he moving door in sight and away from people and objects until the door is completely closed NO ONE R O O D G N I V O M E H T F O H T A P E H T S S O R C D L U O H S 4 NEVER GO UNDER A STOPPED PARTIAL...

Страница 10: ...autions s Disconnect power from opener and disconnect carriage in rail from bullet before beginning this task Visually inspect the chain or belt every 6 months NOTE Tension adjustments should be made...

Страница 11: ...ntil you reach desired setting FORCE SETTINGS DONE PROGRAM SET Press Release PROGRAM SET FORCE ADJUSTMENT 1 2 3 4 5 USE CHART BELOW Press either until you reach the desired setting USE CHART BELOW LOC...

Страница 12: ...removing cover 1 2 3 4 5 6 1 2 3 7 6 POWER CORD CONNECTOR WHITE BLACK GREEN WHITE WHITE BLACK RED BLACK STRIPED WHITE WALL CONSOLE SCREW DRIVE MOTOR STRIPED WHITE SAFE T BEAM 5 4 3 2 1 Purchased Sepa...

Страница 13: ...l console button until door is completely closed s Check for interference from adjacent Safe T Beam units s ContactThe Genie Company at 1 800 35 GENIE Door starts down then STOPS before it is closed O...

Страница 14: ...WUDQVIHUDEOH RU DVVLJQDEOH 7KLV ZDUUDQW DSSOLHV RQO WR 3URGXFW LQVWDOOHG LQ D UHVLGHQWLDO RU RWKHU QRQ FRPPHUFLDO DSSOLFDWLRQ W GRHV QRW FRYHU DQ 3URGXFW LQVWDOOHG LQ FRPPHUFLDO RU LQGXVWULDO EXLOGLQJ...

Отзывы: