background image

4

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Figure 1   Note Door Type

SECTIONAL DOOR, TORSION SPRINGS

SECTIONAL DOOR, EXTENSION SPRINGS

ONE-PIECE DOOR, TRACKLESS

 

 

 

 

          

m

eaSuRe

 G

aRaGe

 D

ooR

 h

eiGht

A  Measure door height (floor to top of door) using a tape measure .
B  This new Garage Door Opener is designed for doors up to and 

including 7’ 6” tall . If door height is 7’ 6” or less continue to Check Step 4 . 
C 

If door height is 8’-0”, you need a Rail Extension Kit . (Figure 3) .

(See Accessories Order Form, Page 16) .
D  If the door height is taller than 8’-0”,  the opener you purchased is 

the wrong version . Contact your Customer Service Representative  

 

at 1-800-354-3643 .

 Check Step 3:

p

Re

-i

NStallatioN

 C

heCkliSt

This Opener includes parts and supplies needed to install in most 

garages and connect to most garage doors .  There are many variations 

of garages and garage doors .  A few additional parts and supplies may 

be needed to install Opener into your garage and connect to your 

garage door .   While checking items listed below, note any additional 

items you will need .

 Tools used in this section:

 12’+ Tape Measure        Pencil        Ladder       Level

Check following items before assembling Opener: 

 

 

 

 

 

C

heCk

 D

ooR

 C

oNDitioN

 

 

         

aND

 t

hiCkNeSS

 Check Step 1:

 

 

 

 

 

C

heCk

 G

aRaGe

 D

ooR

    

 

         

a

liGNmeNt

, o

peRatioN

,  

 

         

aND

 b

alaNCe

 Check Step 2:

          

   

  WARNING:

If your door sticks, binds, or is out of balance, have it adjusted 

by a Genie Factory Authorized Dealer .  Door springs, cables,  

pulleys, brackets and associated hardware are under extreme 

tension and can cause serious injury or death .

Torsion 
Springs

Extension 
Springs

Center

Stile

Center Stile

Header Area

Figure 3   Rail Extension Kit

Rail Extension for 

8’ door

Check condition of vertical stile in center of door, and its connection to 

door’s top and bottom beams . (Figure 1)
A  If door frame is nailed together and not a solid connection, door 

frame must be braced or reinforced before installing Opener .
B  If door is “lightweight” (made with frame and skin - not solid), 

door (including door frame) must be braced or reinforced before 

installing Opener . 
C   A door opener reinforcement bracket may also be needed to  

connect garage door to Opener’s Door Bracket .  This Opener is 

designed for installation on a properly braced sectional door or  

solidly braced one-piece door . 
D  Contact your Genie Factory Authorized Dealer or dealer of your 

garage door for any necessary bracing and a door opener    

reinforcement bracket (if needed) before proceeding .
E 

If you have a wooden door, measure door’s thickness . If your door  

is less than 2” thick,  brace door or use shorter Door Bracket Lag Screws 

(1/4” x 1-1/4” – not included)

A  Raise door, check alignment and see if it moves freely (Figure 2) .  

If door appears out of alignment, binds, or does not move smoothly,  

contact a Genie Factory Authorized Dealer or dealer of your garage 

door for repairs and adjustments to door mechanism . 
B  Raise door to 3’ – 4’ above ground and carefully let go .  Door 

should stay stationary .  Slight movement is acceptable .  More than 

slight movement means door is out of balance .  Contact a Genie 

Factory Authorized Dealer or dealer of your garage  

 

 

door for repairs and adjustments to door  mechanism . 

B  Find Header Bracket mounting height  (Figure 4):  (Do not attach 

Header Bracket) .
 

 

Raise door, watching top edge of door and stop door  

 

 

 

when its edge reaches its highest point .

 

 

Measure distance (“H”) from top edge of door to floor .

 

 

– 

For sectional doors, add 2-1/2” to “H” .   Mark a point    

 

 

 

on center line .  Bottom of Header Bracket will be 

 

 

 

 

installed here .

 

 

– 

For one-piece doors, add 6” to “H” .  Mark this point on     

 

 

 

center line .  Bottom of Header Bracket will be  

 

 

 

 

installed here .

 

 

 

 

 

C

heCk

 D

ooR

 h

eaDeR

 a

Rea

A  Find vertical center line of door and header:   

 

 

 

 

Close door . 

   

 

 

 

 

 

 

Measure door width at top .   

 

 

 

 

 

Mark a point at center of door and on header directly  

 

 

 

above door .  Draw a center line to connect points . 

 Check Step 4:

          

                NOTE

The header is a heavily reinforced section of the wall just 

above the top of the garage door opening . 

H + 2-1/2

H + 6

Figure 4  Find Highest Point of Travel

SECTIONAL DOOR

ONE-PIECE DOOR

HEADER

HEADER

H + 2-1/2

H + 6

C 

Check door type .  Make a note of whether it is a sectional or a  

one-piece door for reference later (Figure 2) .

3’ - 4’

Sectional 

Door

3’ - 4’

Figure 2  Checking door balance

One-Piece 

Door

KEEP FEET CLEAR OF DOOR

Содержание H8000-07

Страница 1: ...F U T U R E R E F E R E N C E Complete with INTELLICODE Remote Control and SERIESII Electronics Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Mode...

Страница 2: ...by an authorized dealer Genie will provide all required parts under war ranty at no charge to you but the dealers are independent business people and may render a bench or ser vice call charge for the...

Страница 3: ...em Places an invisible beam across door opening that reverses the door during down travel to the fully open position if anything passes through beam Safe T Reverse Contact Reversing System Automatical...

Страница 4: ...fore installing Opener C A door opener reinforcement bracket may also be needed to connect garage door to Opener s Door Bracket This Opener is designed for installation on a properly braced sectional...

Страница 5: ...overheating conditions Do Not use portable generator This product is designed to operate using standard house current Do Not use alternate power supplies A Check that there is a 15 Amp 120 Volt groun...

Страница 6: ...store p GER 2 Emergency Release Kit for entry during power failure store p Wood for header ceiling and or door braces store p Masonry fasteners for Safe T Beam Bracket installation store p Safe T Beam...

Страница 7: ...ge door will move slowly the first time it runs until the Opener learns the type of door Ensure the Magnetic Carriage Assembly is engaged and is between the two Limit Switches before operating the Ope...

Страница 8: ...utton again Red Learn Indicator Light will go out indicating that memory is stored B Program each additional Remote using step A above up to seven remotes NOTE Each Remote Control must be programmed s...

Страница 9: ...re MA 3 Pop off the back of the transmitter Use coin pen screwdriver or any similar device Replace old Battery with new coin type battery Replace back of remote B FOR FLASHLIGHT MODELS Pry open batter...

Страница 10: ...the Opener still fails contact a Genie Factory Authorized Dealer for service or call Customer Service at 1 800 35 GENIE NOTE Use ONLY Genie Lubricant GLU 3 Other lubricants may damage the Opener FCC A...

Страница 11: ...a rate of 5 cycles per 10 minutes of rest Over cycled Contact Customer Service for further assistance 4 BLINKS Force Settings Check Force Settings NOTE Force Settings are not pre set at factory 1 See...

Страница 12: ...circuit and for proper wiring Check Open Force adjustment see Set LimitSwitches and Force Controls on page 7 Adjust as needed Check condition of garage door and door spring s WARNING If you suspect a...

Страница 13: ...10 Noisy operation Ensure all fasteners are tightened Check that the garage door and Opener are in good repair properly lubricated and properly balanced See Maintenance page 10 WARNING If you suspect...

Страница 14: ...ved Door Arm main carton 1 35 3 8 x 7 8 Hex Head Bolt yellow bag 2 36 3 8 Hex Serrated Flange Nut yellow bag 2 37 2 Conductor Wire main carton 1 Roll 38 Insulated Staple red bag approx 30 40 Wall Cons...

Страница 15: ...15 For Help call 1 800 35 GENIE or visit www geniecompany com Hardware Exploded View NOTE Opener will not function unless Safe T Beam System is installed and Force Controls are properly set...

Страница 16: ...nge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60 WATT Enhanced Rough Service Light Bulb Ensures proper equipment compatability Bombilla de 60 Vatios...