5-9 Valve Coils
5-9
Valve Coils
How to Test a Coil
A properly functioning coil provides an
electromagnetic force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil. Zero resistance or infinite resistance
indicates the coil has failed.
Since coil resistance is sensitive to temperature,
resistance values outside specification can
produce erratic operation. When coil resistance
decreases below specification, amperage
increases. As resistance rises above specification,
voltage increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: If the machine has been in operation, allow
the coil to cool at least 3 hours before performing
this test.
1
Tag and disconnect the wiring from the coil to
be tested.
2
Test the coil resistance using a multimeter set
to resistance (W). Refer to the Valve Coil
Resistance Specification table.
Result: If the resistance is not within the
adjusted specification, plus or minus 10%,
replace the coil.
Valve Coil Resistance
Specifications
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / -7.7°C
that your air temperature increases or decreases
from 68°F / 20°C.
Description
Specification
Solenoid valve, 3 position 4 way,
20V DC with diode (schematic item F,
AC or DC)
27.2
Ω
Solenoid valve, 3 position 4 way,
20V DC with diode (schematic item E)
19
Ω
Solenoid valve, 2 position 4 way,
20V DC with diode (schematic item H, AI
or DI)
19
Ω
Solenoid valve, 2 position 2 way,
N.C. 20V DC with diode (schematic item
N)
25
Ω
Solenoid valve, 2 position 4 way,
20V DC with diode (schematic item AE or
DE)
19
Ω
Solenoid valve, 3 position 5 way,
20V DC with diode (schematic item AG or
DG)
19
Ω
Solenoid valve, 2 position 2 way,
20V DC with diode (schematic item CA,
CB, CC and CD
27.2
Ω
Solenoid valve, 3 position 4 way,
20V DC with diode (schematic item BA)
19
Ω
Proportional solenoid valve, 2 position
2 way,
20V DC with diode (schematic item DN)
23.9
Ω
Содержание GS-1530
Страница 168: ...Service and Repair Manual September 2016 152 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 210: ...Service and Repair Manual September 2016 194 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 237: ...September 2016 Service and Repair Manual 221 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 240: ...Service and Repair Manual September 2016 224 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 291: ...September 2016 Service and Repair Manual 275 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 294: ...Service and Repair Manual September 2016 278 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 331: ...September 2016 Service and Repair Manual 315 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 335: ......