11 Select the
Reprogram Device
(s) button to
start the ECM software update.
Result: The following screen will be displayed
after the software update is complete.
Note: Do not turn off power while the ECM is being
reprogrammed.
12 Select the
Run Application
button to exit the
software update mode.
13 Push in the red Emergency Stop button and
disconnect the CAT5 cable from the GCON.
14 Secure the diagnostic port cover using the
retaining fasteners removed in step 5. Do not
over tighten.
Note: Machines equipped with AGM batteries will
need to select the AGM battery type using the
GCON set parameters screen. Refer to the
Machine Setup
procedure in the Service and
Repair manual that is appropriate for your machine.
Tip over hazard. Updating the
SmartLink software may have
impacted the machines default
drive speeds. Tipping over the
machine will result in death or
serious injury.
Perform drive speed test. Refer
to the
Maintenance Manual
that
is appropriate for your machine.
15 Perform a function test. Refer to the
Operator's Manual on your machine.
16 Return the machine to service.
Machine Application Mode
1
Open the GCON compartment.
Note: Some models will require opening the ground
control box to access the GCON.
2
Turn the key switch to ground controls or
platform controls and pull out the red
Emergency Stop button to the on position at
both ground and platform controls.
3
Locate the diagnostic port on the side of the
GCON. Remove one of the fasteners securing
the cover and set aside. Loosen the other
fastener. Do not remove it.
a diagnostic port
4
Connect one end of a CAT5 Ethernet cable
into the diagnostic port. Connect the other end
into a PC or laptop.
Result: The ground controls LCD display will
show the following:
Содержание GS-1530
Страница 168: ...Service and Repair Manual September 2016 152 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 210: ...Service and Repair Manual September 2016 194 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 237: ...September 2016 Service and Repair Manual 221 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 240: ...Service and Repair Manual September 2016 224 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 291: ...September 2016 Service and Repair Manual 275 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 294: ...Service and Repair Manual September 2016 278 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 331: ...September 2016 Service and Repair Manual 315 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 335: ......