![Genie GS-1530 Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/genie/gs-1530/gs-1530_service-and-repair-manual_2211838084.webp)
Service and Repair Manual
September 2016
Manifolds
68
GS-30 • GS-32 • GS-46 • GS-47
Part No. 1272217
6
Move and hold the joystick fully in either
direction while observing the pressure reading
on the pressure gauge. Note the pressure.
Refer to Specifications,
Hydraulic Component
Specifications.
7
Turn the machine off. Hold the system relief
valve with a wrench and remove the cap
(schematic item I, AB or DB).
8
Adjust the internal hex socket. Turn it
clockwise to increase the pressure or
counterclockwise to decrease the pressure.
Tip-over hazard. Failure to adjust
the relief valves to specification
could result in the machine
tipping over, causing death or
serious injury. Do not adjust the
relief valve pressures higher
than specifications.
9
Install the relief valve cap.
10 Repeat steps 5 and 6 to confirm the relief
valve pressure.
11 Place maximum rated load into the platform.
Secure the load to the platform. Refer to
Specifications,
Machine Specifications.
GS-32, GS-46 and GS-47
1 test port
2 system relief valve
3 steer relief valve
4 lift relief valve
12 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
13 Hold the lift relief valve with a wrench and
remove the cap (schematic item C, AJ or DJ).
14 While activating the platform up function,
adjust the internal hex socket clockwise, just
until the platform fully rises.
15 Fully lower the platform to the stowed position.
16 Add an additional 50 pounds / 22.7 kg to the
platform. Secure the additional weight.
17 Attempt to raise the platform.
Result: The power unit should
not
be able to
lift platform.
Result: If the power unit lifts the platform,
adjust the internal hex nut socket
counterclockwise until the platform will not
rise.
18 Install the relief valve cap.
19 Remove the weight from the platform.
20 Bleed the hydraulic system by raising the
platform to full height. If the pump cavitates or
the platform fails to reach full height, add
hydraulic oil until the pump is functioning
correctly. Do not overfill the hydraulic tank.
Содержание GS-1530
Страница 168: ...Service and Repair Manual September 2016 152 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 210: ...Service and Repair Manual September 2016 194 GS 30 GS 32 GS 46 GS 47 Part No 1272217 This page intentionally left blank ...
Страница 237: ...September 2016 Service and Repair Manual 221 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 240: ...Service and Repair Manual September 2016 224 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 291: ...September 2016 Service and Repair Manual 275 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 294: ...Service and Repair Manual September 2016 278 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 331: ...September 2016 Service and Repair Manual 315 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 335: ......