2.3 Baud Rate Set-up

Baud rate and corresponding DIP status as below:

RS485 control bus needs all devices that connect to it in parallel mode, and each 

end of the system shall be connected to a 120ohm resistor. The PTZ has a 120ohm 

resistor in it, so you only need to set it up through dip switch SW2, put the 4th 

switch on, then the resistor is connected, details as below :

Resistor is connected 

Resistor isn’t connected

2.4 ID Set-up

ID setup (address code setup obey binary rules) address code shall be set through 

8 DIP switch (SW1). Keyboard control speed dome through communication bus, 

one keyboard can control max. 255pcs speed dome camera, each speed dome 

camera has its own address code, user can set address code through 8 DIP switch, 

details as below:

2400bps

4800bps

9600bps

1    2

ON

1    2

ON

1    2

ON

1    2

ON

Baud  Rate

Automatic  identify

ON

1    2   3   4

ON

1    2   3   4

1     2345678

                             

ON

Содержание GAHD18IRPTZ

Страница 1: ...User Manual Please read these instructions carefully before operating the unit and keep for further reference 1080p AHD 18x Optical Zoom External 360 PTZ Camera with Wall Bracket GAHD18IRPTZ ...

Страница 2: ...oth to wipe If it is too dirty please use a neutral cleaner to wipe lightly Do not use a strong cleaner and scrub otherwise housing can scratch Prevent liquid or other things getting into the housing to prevent any damage Please do not use the camera beyond its limited temperature and humidity 25 C to 50 C humidity less than 90 Please do not install the camera near an air conditioner outlet or any...

Страница 3: ... Power Supply and Control Cable Connection 10 2 6 Connection Method 10 2 7 Cabling Mark Instruction 10 2 8 Typical Application Wiring Diagram 10 3 0 Basic Operation 11 3 1 Power On Self Test 11 3 2 Preset Setting 11 3 3 Call a Preset 11 3 4 Function by Preset 12 3 5 Patrol Setting 15 4 0 FAQ s and General Info 16 4 1 FAQ s 16 4 2 Cleaning the Transparent Cover 16 4 3 Lightning and Surge Protection...

Страница 4: ...oduction Electric Rated Voltage DC12V 4A 10 Power Consumption 10 Max at daytime 30Max at night without heating Decoder Built in IR Distance 100 120m Set Communication Protocol PELCO D P ID 1 255 Baud Rate RS485 2400 4800 9600bps auto identify Operate Pan Rotate 360 endless Tilt Rotate 90 Speed Middle Speed Pan 6 30 S Tilt 4 17 S High Speed Pan 0 1 200 S Tilt 4 30 S Preset 220 Monitor Mode Preset P...

Страница 5: ...x Optical Zoom External 360 PTZ Camera with Wall Bracket 5 1 3 Product Dimensions Unit mm 241 2 136 1 332 8 136 1 251 1 136 1 208 0 114 9 154 0 130 0 62 0 80 0 96 0 4x 7 0 114 6 66 1 83 7 3 5 124 3 3 4 0 120 0 29 9 30 9 135 0 ...

Страница 6: ... camera transparent cover and other parts 2 2 Installation Method Step 1 Draw positioning holes Take out the bracket from packaging box Mark the holes position based on the wall mount bracket bottom 4pcs installation holes Wall Mount Bracket Ceiling Mount Bracket Step 2 Drill holes and put expansion screws in Drill 4pcs expansion screw s installation holes at pre marked position then put 4pcs expa...

Страница 7: ...r from speed dome camera Step 4 Set up DIP switch Please refer to section 3 Baud rate setup Step 5 Install transparent cover of DIP switch After finishing baud rate setup install transparent cover of DIP switch again Step 6 Lead cable through wall mount bracket Lead the cable through the wall mount bracket hole Step 7 Connect PTZ camera and wall mount bracket Put PTZ camera connection port into br...

Страница 8: ...s on wall mount bracket and lead the cable out from the wiring port then fix it onto the wall by using 4 screws Seal the wiring port of the bracket by using silicon sealant Step 9 Cable connection Please refer to section six of this chapter Connection method Step 10 Tear off protection film Teal off protection film of transparent cover Note Please take care of transparent cover ...

Страница 9: ...itch SW2 put the 4th switch on then the resistor is connected details as below Resistor is connected Resistor isn t connected 2 4 ID Set up ID setup address code setup obey binary rules address code shall be set through 8 DIP switch SW1 Keyboard control speed dome through communication bus one keyboard can control max 255pcs speed dome camera each speed dome camera has its own address code user ca...

Страница 10: ...board controller or DVR if there is more than one that needs to be controlled by keyboard or DVR please connect it in parallel Note 1 Protocol and baud rate of keyboard and DVR can be set by customer just make sure it is the same with that PTZ 2 The ID of different camera which is in same system shall be set as different 3 It should set the difference PTZ Camera Address in Monitor system with mult...

Страница 11: ...mera will also move to the right and when moving the joystick left the camera will also move to the left Moving the joystick in a tilt direction the camera also will make corresponding action in tilt direction If you move the joystick in a diagonal direction it can make the camera move in a pan and tilt direction action at the same time with the movement direction same as the joystick 3 2 Preset S...

Страница 12: ...General Function and Preset Function of Specific Function Call Mode Call mode is on in general preset of call specific function is achieved by the mode of preset call for example 92 SHOT 1 SHOT which is to call patrol 1 Setting Mode Setting mode is on in general preset of setting specific function is achieved by the mode of preset call for example 92 PRESET 1 SHOT which is to set patrol 1 Preset F...

Страница 13: ...User Manual 1080p AHD 18x Optical Zoom External 360 PTZ Camera with Wall Bracket 13 ...

Страница 14: ...User Manual 1080p AHD 18x Optical Zoom External 360 PTZ Camera with Wall Bracket 14 Remark Preset 35 could run Patrol 1 Default Preset Point No 1 No 8 ...

Страница 15: ... example add 1 4 presets in patrol 1 standing time 30s speed 40 follow the instructions below Add preset in patrol path 1 Set preset 92 call preset 1 start patrol 1 setting 2 Call preset 1 add preset 1 to patrol 1 3 Call preset 2 add preset 2 to patrol 1 4 Call preset 3 add preset 3 to patrol 1 5 Call preset 4 add preset 4 to patrol 1 6 Call preset 92 then call preset 9 save patrol 1 The setting o...

Страница 16: ...ease be careful and avoid touching the transparent cover directly Any scratches of the flint on the transparent cover will lead to a foggy image affecting the image quality Please use soft enough dry cloth or other replacement to wipe the inner and surface If seriously dirty use a neutral cleanser 4 0 FAQ s and General Info ...

Страница 17: ... It needs to add extra high frequency thunder proof device and lightning rod in strong thunderstorms area or high inductive voltage region such as high voltage substation Thunder proof and grounding design of exterior installation and circuit must be in accordance with building lightning proof requirements It must meet national standard and industry standard System must be equipotential grounding ...

Страница 18: ...24AWG screen twisted pair cable as communication cable Depending on different baud rate the longest transmitting distance theoretical value is shown as below The longest transmitting distance of baud rate 2400Bps 1800m 4800Bps 1200m 9600Bps 800m Connection mode and terminal resistance RS485 industry bus standard require adopt snake like wiring chrysanthemum chain the ends must connect with 120Ω te...

Страница 19: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk ...

Отзывы: