background image

2

Things to consider if you are planning to “do-it-yourself.”

Whether you are replacing an existing garage door operator or installing an operator in your
garage for the first time, there are some pre-installation issues which need to be addressed.
They are as follows:

The Genie Company recommends that you read and fully understand all 

information and instructions contained herein before choosing a 

do-it-yourself

installation. Any questions should be directed to the Genie Company or an authorized
Genie Dealer.

6

To avoid damage to your door and/or         

operator, make sure you disable any door

locks prior to installing your operator

.

PRE-INSTALLATION CHECK LIST   

FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM

1

Check your ceiling where the power 
head of your new unit will be mounted
.

Plan how you will be mounting the power head.
It is possible that ceiling joists may not be in the
exact position needed with respect to the garage
door operator. It may be necessary to add an
additional bracket and fasteners (not included
with your new door operator kit).

2

Check the wall directly above the garage
door

.

The door operator’s header bracket

must be securely fastened to this wall. Ensure
that the structure will provide a strong mounting
location.

3

Check to see if the mounting location   
for the Safe-T-Beam

®

System (STBis

clear from obstruction and has a wood 
surface available for attaching the STB brack-
ets

.

The brackets may be attached to concrete if

necessary but extra tools and special fasteners
(not supplied) will be required.

NOTE: 1-1/2" STB bracket adapters are 
available through your local Genie Dealer.

4

Is your garage door made of 
light-weight steel, aluminum, fiberglass

or glass panels

?

Additional support bracing

must be added to these type doors. If this is the
case, please contact the door distributor or 
manufacturer so that they can furnish you with a
“bracing kit.”

7

Ensure that your door is properly balanced 
and moving freely. 
SEE WARNING BELOW.

If your door sticks, binds, or is out of 
balance, have it adjusted by a professional.
Door springs, cables, pulleys, brackets and
associated hardware are under extreme 
tension and can cause serious injury or
death.

WARNING

(The issue numbers below refer to the circled numbers in the illustrations on page 3.

)

8

(NOT SHOWN) If your garage does not have
a separate entry door, 
you should consider

an emergency release kit (GER-2) for installation 
on your garage door. See page C at the center of
this manual.

DO NOT USE AN EXTENSION CORD!
Extension cords can cause dangerous
overheating conditions.
DO NOT USE A PORTABLE GENERATOR!
This product is designed to operate on
standard house current. Do not use 
alternate power supplies.

WARNING

5

You need a 110-120 Volt power supply 
available

.

The outlet should be no more than 

3 feet from the power head once it is mounted. (The
cord is 4 ft. in length.) SEE WARNING BELOW.

HomeLink® is a  universal 
transceiver (a combined

transmitter and receiver), that provides a 
convenient way to replace up to three hand-held
radio-frequency (RF) transmitters used to 
activate devices such as gate operators, garage
door openers, entry door locks, security systems
and even home lighting. Additional HomeLink

®

information can be found at: www.homelink.com
or by calling 1.800.355.3515

.

Содержание CM7600 Series

Страница 1: ...lose door SAVE THIS MANUAL FOR FUTURE REFERENCE NOTE Your Residential Operator comes with a Rail Assembly which is standard for up to a 7 foot 6 inch high door An extension kit for an 8 foot high door...

Страница 2: ...uired NOTE 1 1 2 STB bracket adapters are available through your local Genie Dealer 4 Is your garage door made of light weight steel aluminum fiberglass or glass panels Additional support bracing must...

Страница 3: ...ION 5 TYPICAL SUPPORT BRACKET EXTENSION SPRING OR TORSION SPRING SAFE T BEAM BRACES ADDED HEADER BRACKET MOUNTING BOARD 36 POWER CORD TO 120V GROUNDED OUTLET 6 4 3 1 2 3 7 SECTIONAL DOOR 1 PIECE DOOR...

Страница 4: ...er Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance SAFETY FEATURES varies by model TABLE OF CONTENTS SECTION PAGE PRE INSTALLATION CHECK...

Страница 5: ...by continuously changing the access code each time the remote control is used The door operator responds to each new code only once An access code copied from a working system and tried again will no...

Страница 6: ...4 20 Hex Flange Nut 2 2 6 Carriage Stop 1 1 7 Rail Clamps 4 8 5 16 Hex Shoulder Bolt 8 9 5 16 Hex Flange Nut 5 13 10 Carriage Assembly 1 1 11 Collar 2 12 Retaining Clip 2 13 Rail Strap 1 1 15A Open L...

Страница 7: ...3 Wall Console varies varies 34 6 x 1 1 4 Pan Head Screw 2 2 35 Entrapment WARNING Label 1 1 36 Safe T Beam STB System Sensor Green LED 1 1 37 Safe T Beam STB System Source Red LED 1 1 38 Safe T Beam...

Страница 8: ...32 remotes vary by model Rubber bumper 1 4 x 2 Lag screw 5 16 Flange nut 3 8 Hex head bolt 3 8 Nut 10 x 1 1 4 Phillips hex head screw 1 4 Flange nut Insulated staple Coupler 8 32 x 3 8 Hex head screw...

Страница 9: ...the risk of severe injury or death WARNING SAFETY INFORMATION PRE INSTALLATION WARNING SAVETHESE INSTRUCTIONS Visit our website at www geniecompany com FILL THIS IN AT TIME OF INSTALLATION FOR YOUR O...

Страница 10: ...o power head 3 piece only Select first rail section It has protective cardboard sleeve over end of screw Fig 1 2 3 piece only Remove cardboard sleeve Slide end of screw out about 5 inches Fig 1 3 Plac...

Страница 11: ...both ends with each set of holes being about 4 inches apart Fig 1 6 Find arrows stamped into side of rail Fig 1 7 Align rail so arrows point away from power head Slide screw toward power head so it s...

Страница 12: ...ig 1 10 Snap a clip 12 onto screw behind collar to hold collar in place Fig 1 11 Slide middle rail against first rail Place rail clamp 7 on each side of joint where rails meet Match up holes in clamps...

Страница 13: ...ig 1 14 is pointing away from power head Emergency release lever will be facing power head Slide carriage into rail Fig 1 15 NOTE Carriage can be used as a temporary support for the rail while perform...

Страница 14: ...n inside groove in top of rail back to power head Use wire clip 44 to help maintain slack Fig 1 20 OPEN limit switch 15A Place OPEN limit switch over top of rail about 12 inches from power head Fig 1...

Страница 15: ...e panel and swivel on large spring loaded hinges on each side of door 1 Determining header bracket location Find center of door from side to side Measure overall width of door example 16 feet Divide o...

Страница 16: ...top edge to the floor Remove support and gently lower door Mark highest point of travel at centerline on wall above door Fig 2 3 NOTE Following step depends on type of door 3 Final header bracket moun...

Страница 17: ...re rail strap attaches is on centerline Fig 2 6 Mark screw hole locations If your wall is finished take a small finish nail and gently tap it through drywall where you have marked screw holes to find...

Страница 18: ...rial between power head and floor to prevent scrapes and scratches to power head NOTE It may be necessary to support power head above floor As little as a few inches or as much as 5 or 6 feet dependin...

Страница 19: ...clear door by about 2 inches Fig 2 10 using one of the preferred methods shown Fig 2 11 mount power head It is possible to use other mounting methods The critical point to remember is that the mountin...

Страница 20: ...of sectional doors the door bracket must not be below the highest set of rollers Fig 2 13 there are a wide variety of reinforcements depending on manufacturer and some are equipped with hardware that...

Страница 21: ...Use clevis pin 24 and cotter pin 25 Fig 2 14 Connect straight arm to door bracket Use clevis pin 24 and cotter pin 25 Overall length of arms together should be as long as possible Fig 2 14 a Move carr...

Страница 22: ...2 Mounting STB source and sensor If garage has only one garage door Determine which side of garage receives most direct sunlight Fig 3 4 and place Red LED here whenever possible Fig 3 4 For multiple d...

Страница 23: ...e and sensor Ensure that tops of lenses are between 5 6 above the floor Fig 3 9 The brackets are flexible and can be adjusted slightly if needed NOTE Safe T Beam alignment check will be performed foll...

Страница 24: ...Tighten screws 4 Mount wall control Fig 4 4 For Wall Console or Wall Button Use pan head screws 34 5 Mount entrapment warning label Fig 4 4 Remove protective backing Stick label to wall next to wall c...

Страница 25: ...lights on and off without moving door 2 Wall Button Operates door from inside garage A B C SECT 5 LIGHT LENS INSTALLATION FOR HELP 1 800 354 3643 1 Install light bulbs 2 bulbs No more than 60 watts e...

Страница 26: ...ad NOTE There must be at least 6 inches of black and white wire inside the power head Between splice and entrance bushing Remove and throw away power cord strain relief and knock out 5 Install suitabl...

Страница 27: ...serve door runs to CLOSE limit switch If not increase closing force by turning CLOSE adjusting screw clockwise slightly about 1 16 turn Repeat until door runs to CLOSE limit switch Check door is fully...

Страница 28: ...act reverse works properly If you don t have a 2 x 4 board handy any object 1 1 2 inches high that can withstand being hit by the garage door without sustaining damage is fine NOTE If door is stopping...

Страница 29: ...at up or down limit door will move away from that limit If door is stopped between limits it will move toward the limit where it was last stopped If door is moving it will stop NOTE Door automaticall...

Страница 30: ...anadas abweichen Les metteurs sont conformes la r glementation am ricaine et canadienne compter de leur date de fabrication Aucune garantie n est stipul e indiquant qu ils sont conformes toutes les pr...

Страница 31: ...WALL CONTROL BUTTON DOWN UNTIL DOOR IS CLOSED REMOTE CONTROL WIRELESS KEYPAD WILL NOT WORK WITHOUT STB SOURCE RED LED SENSOR GREEN LED INDICATED CONDITION REQUIRED ACTION 2 BLINKS PAUSE REPEAT 3 BLINK...

Страница 32: ...switch setting See section 7 Check force adjustment See section7 Check for broken door spring Operator runs but door does not move Make sure carriage is engaged Check force adjustment See Section 7 O...

Страница 33: ...ROWN ORANGE GREEN GREEN GREEN GREEN OPEN ABRIR OUVRIR CLOSE CERRAR FERMER LIGHTS LUZES LAMPES WHITE GREEN POWER CORD CORDON DE ALIMENTACION CABLE D ALIMENTATION SEQUENCEUR PRIMAIRE SECUENCIADOR PRIMAR...

Страница 34: ...del producto 1 Servicio de bricolaje Llamar sin cargo a la conexi n del consumidor de Genie marcando el 1 800 354 3643 Representantes entrenados de Genie le asistir n en diagnosticar el problema y ha...

Страница 35: ...tor to accommodate eight foot door GSX 8 Juego de extensi n deslizante de Screw Drive Una extensi n de 18 pulgadas para aumentar la carrera de un abridor deslizable de tornillo para acomodar una puert...

Отзывы: