Genie Chainlift 2020 Скачать руководство пользователя страница 9

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

9

Coarse Setting of Limit Switches

A

Setting Close Limit Switch (

Figure 9

):

Check that Magnetic Carriage Assembly is disengaged.

With garage door fully closed, slide Close Limit Switch 
until it is aligned with Carriage Assembly Magnet.

Tighten Set Screw.

Do Not

over-tighten.

B

Setting Open Limit Switch:

Manually open garage door to full open position.

Slide Open Limit Switch until it is aligned with Carriage 
Assembly Magnet.

Tighten Set Screw.

Do not

over-tighten.

Re-engage Magnetic Carriage Assembly.

Setting Force Controls and Final Adjustment of
Limit Switches

A

CLOSE ADJUSTMENT

On front panel of Power Head find adjusting screw 
marked “CLOSE” (

Figure 9

).

Gently turn screw counterclockwise until it stops.

Very little force is required to turn adjusting screw.

Press Wall Console to close garage door.

Observe if door stops at “CLOSE” limit switch.
If door is fully closed—adjustment is finished.
Go to “OPEN” Adjustment.

If door stops but is not fully closed,
a.

Measure distance between bottom of door 
and floor.

b.

Move “CLOSE” Limit Switch that same distance 
toward door.

If door stops and/or reverses before reaching the 
“CLOSE” Limit Switch
a.

Slightly increase CLOSE Force setting (clockwise).

If door reverses after contacting floor, move Limit 
Switch toward Power Head.

If door fails to move, check Safe-T-Beam® System. See
Troubleshooting Section, pages 15 and 16.

Open adjustment next page.

WARNING

The garage door opens rapidly, and can cause serious 
injury or death.

Keep the path clear.

Position the ladder to the side of the Power Head so it is 
clear of all moving parts of the Opener and the door.

Set the door Opener to use the minimum force needed 
to open the door.

NOTE

Little effort is required to turn the Force             
Adjusting Knobs.

If the door stops moving while opening or 
closing, adjust the Open Force or Close Force 
Controls 

slightly

clockwise (to 

slightly

increase the force) and retry  the step.

The Open Force and Close Force Controls are  to
be set to the 

minimum

force necessary to 

ensure the door smoothly opens and 
closes completely.

Ensure the Carriage Assembly is engaged and is
between the two Limit Switches before 
operating the Opener.

Figure 9

Making Force Adjustments

(Located Lower Right Corner).

C

H

S

ET

L

IMIT

S

WITCHES AND

F

ORCE

C

ONTROLS

A

DJUSTMENT

1:

A

DJUSTMENTS

LOCATED
UNDER
LIGHT
COVER

OPEN
FORCE

CLOSE
FORCE

Содержание Chainlift 2020

Страница 1: ...E R E N C E COMPLETE WITH INTELLICODE REMOTECONTROL AND SERIESII ELECTRONICS Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Model information ready...

Страница 2: ...______ _________ __________ Serial Number ______________________________ Operator Model ______________________________ Remote Control Model ______________________________ Dealer Name _________________...

Страница 3: ...Maintenance Brochure DASMA Entrapment Warning Label To be Adhered in close proximity to wall control Assembly and Installation Poster This poster is intended to give a convenient lay flat media to be...

Страница 4: ...and auto matically turns off 4 5 minutes later Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance IMPORTANT INSTALLATION INSTRUCTIONS 1 REA...

Страница 5: ...t bracket if needed before proceeding E If you have a wooden door measure door s thickness 1 4 x 2 Lag Screws are included for installing Door Bracket onto door If your door is less than 2 thick brace...

Страница 6: ...rk a point on center line Bottom of Header Bracket will be installed here For one piece doors add 6 to H Mark this point on center line Bottom of Header Bracket will be installed here C Check wall for...

Страница 7: ...uit Perforated Angle Iron Figure 6 Mounting methods for open beam or finished ceilings FINISHED CEILINGS Locate ceiling joists or trusses using a stud finder or similar device Attach angle iron not in...

Страница 8: ...elease Kit lets you open garage door from outside if there is a power failure Please see Accessories Order Form on page 20 Check Step 9 Before going further get any items and tools needed for your ins...

Страница 9: ...ch that same distance toward door If door stops and or reverses before reaching the CLOSE Limit Switch a Slightly increase CLOSE Force setting clockwise If door reverses after contacting floor move Li...

Страница 10: ...tion the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door Set the door Opener to use the minimum force needed to open the door A Open garage door usin...

Страница 11: ...e door will move B Press Button again Garage door will stop The door automatically stops at the end of the open or close cycle C Press Button again Garage door will reverse WARNING A moving garage doo...

Страница 12: ...ime If a Remote Control becomes lost or if you want to delete a Remote Control or Wireless Keypad see To Erase All Receiver Memory Transmitter Compliance Statement ABOUTDUAL FREQUENCY REMOTETRANSMITTE...

Страница 13: ...use harmful interference and 2 this device must accept any interference received includ ing interference that may cause undesired operation WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1 READ...

Страница 14: ...14 For Help call 1 800 35 GENIE or visit www geniecompany com NOTES...

Страница 15: ...upted Remove power and reapply 2 BLINKS Pause Beam not aligned Check Source Sensor alignment Repeat ON Beam obstructed Check for obstruction Sensor defective Contact Customer Service 2 BLINKS Pause Wi...

Страница 16: ...4 WARNING Ifyoususpectaproblemwiththegaragedoorhardwareorsprings contactaGenie FactoryAuthorizedDealerforservice orcontactCustomerServiceat1 800 35 GENIE 5 Check Position of Lock Switch on Console Doo...

Страница 17: ...17 For Help call 1 800 35 GENIE or visit www geniecompany com WIRING DIAGRAM WARNING Shut off power before opening the Cover Components inside Cover May Cause Electric Shock...

Страница 18: ...rd Bracket 1 1L Drive Module 1 1M Terminal Strip 1 1N No 8 32 x 3 4 Hex Head Screw w int Lockwasher 1 1P Shock Absorbtion Stop 1 1Q Motor Mount Bracket not shown 1 1X Chassis 1 4 1 4 20 Shoulder Bolt...

Страница 19: ...26 Curved Door Arm main box 1 27 3 8 16 x 7 8 H H Bolt yellow bag 2 28 3 8 16 Hex Flange Nut yellow bag 2 29 Wire main box 1 30 Insulated Staples red bag varies by model Parts List Item Part Name 31 W...

Страница 20: ...ain Glide para acomodar unapuertade8 pies 2 43 m N cessaire de prolongement du coulisseau Rallonge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60WATT...

Отзывы: