Genie Chainlift 2020 Скачать руководство пользователя страница 5

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

5

P

RE

-I

NSTALLATION

C

HECKLIST

This Opener includes parts and supplies needed to install in 

most

garages and 

connect to 

most

garage doors. There are many variations of garages and garage 

doors. A few additional parts and supplies may be needed to install Opener into 

your

garage and connect to 

your

garage door. While checking items listed 

below, note any additional items you will need.

Tools used in this section:

12'+ Tape Measure      

Pencil      

Ladder     

Level

Check following items before assembling Opener:

C

HECK

D

OOR

C

ONDITION AND

T

HICKNESS

Check condition of vertical stile in center of door, and its connection to door’s
top and bottom beams.

A

If door frame is nailed together and not a solid connection, door frame 
must be braced or reinforced before installing Opener.

B

If door is “lightweight” (made with frame and skin - not solid), door 
(including door frame) must be braced or reinforced before         
installing Opener.

C

A door opener reinforcement bracket may also be needed to connect 
garage door to Opener's Door Bracket. This Opener is designed for 
installation on a 

properly braced

sectional door or 

solidly braced

one-piece door.

D

Contact your Genie Factory Authorized Dealer or dealer of your garage 
door for any necessary bracing and a door opener reinforcement 
bracket (if needed) before proceeding.

E

If you have a wooden door, measure door’s thickness. (1/4" x 2") Lag  
Screws are included for installing Door Bracket onto door. If your door 
is less than 2” thick, brace door or use shorter Door Bracket Lag 
Screws (1/4" x 1-1/4" – not included)

Check Step 1:

C

HECK

G

ARAGE

D

OOR

A

LIGNMENT

, O

PERATION

,

AND

B

ALANCE

A

Raise door, check alignment and see if it moves freely (

Figure 1

). If door 

appears out of alignment, binds, or does not move smoothly, contact a 
Genie Factory Authorized Dealer or dealer of your garage door for repairs 
and adjustments to door mechanism.

B

Raise door to 3' – 4' above ground and carefully let go. Door should stay 
stationary. Slight movement is acceptable. More than slight movement 
means door is 
out of balance.
Contact a Genie 
Factory Authorized 
Dealer or dealer 
of your garage 
door for repairs 
and adjustments 
to door 
mechanism.

C

Check door type.
Make  a note of 
whether it is a
sectional or a 
one-piece  door
(

Figure 2

).

Check Step 2:

WARNING:

If your door sticks, binds, or is out of 
balance, have it adjusted by a Genie Factory
Authorized Dealer. Door springs, cables,
pulleys, brackets and associated hardware
are under extreme tension and can cause
serious injury or death.

KEEP FEET CLEAR OF DOOR

3' - 4'

Sectional Door

3' - 4'

One-Piece Door

Figure 1

Checking door balance

Figure 2

Note Door Type

Torsion 

Springs

Extension 

Springs

Center

Stile

Center Stile

Header Area

Header 

Area

Header 

Area

SECTIONAL DOOR, TORSION SPRINGS

SECTIONAL DOOR, EXTENSION SPRINGS

ONE-PIECE DOOR, TRACKLESS

Содержание Chainlift 2020

Страница 1: ...E R E N C E COMPLETE WITH INTELLICODE REMOTECONTROL AND SERIESII ELECTRONICS Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Model information ready...

Страница 2: ...______ _________ __________ Serial Number ______________________________ Operator Model ______________________________ Remote Control Model ______________________________ Dealer Name _________________...

Страница 3: ...Maintenance Brochure DASMA Entrapment Warning Label To be Adhered in close proximity to wall control Assembly and Installation Poster This poster is intended to give a convenient lay flat media to be...

Страница 4: ...and auto matically turns off 4 5 minutes later Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance IMPORTANT INSTALLATION INSTRUCTIONS 1 REA...

Страница 5: ...t bracket if needed before proceeding E If you have a wooden door measure door s thickness 1 4 x 2 Lag Screws are included for installing Door Bracket onto door If your door is less than 2 thick brace...

Страница 6: ...rk a point on center line Bottom of Header Bracket will be installed here For one piece doors add 6 to H Mark this point on center line Bottom of Header Bracket will be installed here C Check wall for...

Страница 7: ...uit Perforated Angle Iron Figure 6 Mounting methods for open beam or finished ceilings FINISHED CEILINGS Locate ceiling joists or trusses using a stud finder or similar device Attach angle iron not in...

Страница 8: ...elease Kit lets you open garage door from outside if there is a power failure Please see Accessories Order Form on page 20 Check Step 9 Before going further get any items and tools needed for your ins...

Страница 9: ...ch that same distance toward door If door stops and or reverses before reaching the CLOSE Limit Switch a Slightly increase CLOSE Force setting clockwise If door reverses after contacting floor move Li...

Страница 10: ...tion the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door Set the door Opener to use the minimum force needed to open the door A Open garage door usin...

Страница 11: ...e door will move B Press Button again Garage door will stop The door automatically stops at the end of the open or close cycle C Press Button again Garage door will reverse WARNING A moving garage doo...

Страница 12: ...ime If a Remote Control becomes lost or if you want to delete a Remote Control or Wireless Keypad see To Erase All Receiver Memory Transmitter Compliance Statement ABOUTDUAL FREQUENCY REMOTETRANSMITTE...

Страница 13: ...use harmful interference and 2 this device must accept any interference received includ ing interference that may cause undesired operation WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1 READ...

Страница 14: ...14 For Help call 1 800 35 GENIE or visit www geniecompany com NOTES...

Страница 15: ...upted Remove power and reapply 2 BLINKS Pause Beam not aligned Check Source Sensor alignment Repeat ON Beam obstructed Check for obstruction Sensor defective Contact Customer Service 2 BLINKS Pause Wi...

Страница 16: ...4 WARNING Ifyoususpectaproblemwiththegaragedoorhardwareorsprings contactaGenie FactoryAuthorizedDealerforservice orcontactCustomerServiceat1 800 35 GENIE 5 Check Position of Lock Switch on Console Doo...

Страница 17: ...17 For Help call 1 800 35 GENIE or visit www geniecompany com WIRING DIAGRAM WARNING Shut off power before opening the Cover Components inside Cover May Cause Electric Shock...

Страница 18: ...rd Bracket 1 1L Drive Module 1 1M Terminal Strip 1 1N No 8 32 x 3 4 Hex Head Screw w int Lockwasher 1 1P Shock Absorbtion Stop 1 1Q Motor Mount Bracket not shown 1 1X Chassis 1 4 1 4 20 Shoulder Bolt...

Страница 19: ...26 Curved Door Arm main box 1 27 3 8 16 x 7 8 H H Bolt yellow bag 2 28 3 8 16 Hex Flange Nut yellow bag 2 29 Wire main box 1 30 Insulated Staples red bag varies by model Parts List Item Part Name 31 W...

Страница 20: ...ain Glide para acomodar unapuertade8 pies 2 43 m N cessaire de prolongement du coulisseau Rallonge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60WATT...

Отзывы: