WARNING
CAUTION
NOTE: DO NOT connect the Battery Back-Up Connection Cable to the
garage door opener until you have completed Steps 1 & 2.
NOTE: DO NOT REVERSE CONNECTIONS—this WILL
damage the Battery Back-Up Unit.
1
REQUIREMENTS
This unit is designed to work with specific garage door openers on properly
balanced doors with maximum height of 8 ft. and maximum weight of 500 lb.
The unit will provide operation of the door for 24 hours after a power loss.
Your garage door opener MUST have the matching Connection Cable
connector in the powerhead.
Do not tamper with or rewire Connection Cable.
Unit may be wall mounted provided mounting location is within 24 inches
of the powerhead.
The unit must be inserted into the mounting bracket as far as it will go, so
that the bracket locks onto the ridges (Figure at Top Right) on top of the
Battery Back-Up unit. This prevents the unit from moving.
The unit must be mounted so that the Status LEDs are visible from the floor,
and it is locked into the mounting bracket.
This unit to be used ONLY with Genie® Operator Models
Disconnect power before performing the following tasks.
Do NOT drill holes in the Battery Back-Up case.
RIDGES
4 SCREWS
COVER
MOUNTING
BRACKET
LAG SCREWS
RAFTER
OR
TRUSS
To Reduce the Risk of Fire
or Injury to Persons
To Prevent possible Serious
Injury or Death by Electrocution
A. Use only the following type and size battery 12V, 8Ah
(Genie® P/N 37342R).
B. Do not install Battery Back-up unit on an improperly balanced
door. An unbalanced door could cause severe injury or damage to
this unit. Repairs and adjustments to the door must be made by
trained service persons using proper tools and instructions.
C. Do not dispose of the battery in fire. The cells may explode.
Check with local codes for possible disposal instructions.
D. Do not open or mutilate the battery. Released electrolyte is
corrosive and candamage eyes or skin. TOXIC if swallowed.
E. Exercise care in handling the battery to prevent shorting battery
with conducting materials such as rings, bracelets & keys.
F. Change the battery provided with or identified for use with
this product only in accordance with the instructions and
limitations specified in this instruction.
G. Observe proper polarity orientation between the battery and
changing circuit.
H . Do not set limits while in Battery Back-up Mode. AC power
MUST be connected to the opener, while setting limits, for
proper operation.
Battery Back-Up
for Residential Garage Door Openers
INSTALLATION INSTRUCTIONS
37260500131 01-2013
www.geniecompany.com
INSTALLATION
Step 2. Mount
Step 1. Wire Battery
A.
A. Remove Cover (4 screws).
— Remove foam shipping block and throw away.
C. Replace Cover.
B. Connect RED (+) wire to RED terminal,
BLACK (–) wire to BLACK terminal.
Method 1 - Ceiling Mount
Locate and attach mounting plate to ceiling rafter or
truss using two 5/16" x 1-3/4" lag screws (provided).
— Drill 3/16"
pilot holes for lag screws.
Rafter or Truss
(2) 5/16" x 1-3/4" Lag
Mounting
Bracket
Rafter or Truss
Drywall
(2) 5/16" x 1-3/4" Lag
Mounting
Bracket
continued on back
TO P
REV
ENT
POS
SIBL
E
SER
IOU
S IN
JUR
Y or
DEA
TH
from
elec
troc
utio
n AN
D RE
DUC
E RIS
K of
FIRE
— D
iscon
nect
ALL
elec
tric p
owe
r sou
rces
and
batt
ery
po
wer
BEFO
RE p
erfo
rmin
g AN
Y ser
vice
or m
ainte
nanc
e.
Insta
ll on
ly in
DRY
loca
tions
- NO
T INT
END
ED F
OR O
UTD
OOR
USE
.
For u
se O
NLY
with
Gen
ie® m
odel
Seri
es 30
XX o
r 40X
X
Resid
entia
l Gar
age
Doo
r Op
ener
s.
Use o
nly G
enie
P/N
3734
3R
for re
place
men
t bat
tery.
The
Ge
nie
Mo
del
OB
B-B
X
CAU
TIO
N
P
ARA
EVIT
AR P
OSIB
LES
LESIO
NES
GRAV
ES O
MUE
RTE
por e
lectr
ocuc
ión y
PAR
A RE
DUC
IR EL
RIES
GO D
E FU
EGO
— D
esco
necte
toda
s las
fuen
tes d
e ene
rgua
eléct
rica y
la
ba
tería
ante
s de r
ealiz
ar ni
ngún
serv
icio n
i man
tenim
iento
.
Insta
lar só
lo en
luga
res se
cos —
NO E
S PAR
A US
O EN
EXTE
RIOR
ES.
Para
su us
o sól
o con
Gen
ie® m
odel
o de
la se
rie 30
XX o
40XX
abre
puer
tas re
siden
ciale
s par
a pue
rtas d
e gar
aje.
Utilic
e sólo
Geni
e® P/N
3734
3R co
mo b
atería
de re
pues
to.
The
Ge
nie
Mo
del
OB
B-B
X
PREC
AUC
IÓN
3831
0A
Insta
llez u
niqu
eme
nt da
ns de
s end
roits
secs
— P
AS D
ESTIN
E A E
TRE
UTIL
ISE E
N PL
EIN A
IR.
A uti
lizer
uniq
uem
ent a
vec G
enie
® mo
dèle
de la
série
30X
X
ou 4
0XX
pour
port
es de
gara
ge ré
siden
tielle
s.
Utilis
ez un
ique
men
t des
Gen
ie® P
/N 37
343R
com
me
batte
rie d
e rep
lacem
ent.
PO
UR É
VIER
LES
BLES
SURE
S
G
RAVE
S OU
LA M
ORT
par
élect
rocu
tion
et PO
UR R
ÉDU
IRE E
S RIS
QUE
S DE
FEU
— D
ébra
nche
s tou
tes le
s sou
rces d
’alim
enta
tion é
lectr
ique
s et
la
bett
erie a
vant
tout
e rép
arati
on ou
l’ent
retie
n.
ATTE
NTIO
N
®
US
The
Ge
nie
Mo
dèl
e O
BB-
BX
PowerMax®, SC, TriloG™, PowerLift™, SilentMax®, CB
and IntelliG® that are equipped with Series II electronics.
Choose mounting
,
Angle Iron Mount and Method 3 - Horizontal Mount
and attach the mounting plate using screws provided.
Method 1 - Ceiling Mount Method 2 -
Disconnect all electric power sources and battery power
BEFORE performing ANY service or maintenance.
INSTALL ONLY IN DRY LOCATIONS. NOT FOR OUTDOOR USE.
*
READ AND FOLLOW ALL SAFETY WARNINGS, CAUTIONS
AND THESE ENTIRE INSTRUCTIONS PRIOR TO BEGINNING!
Mounting
Plate
Connection
Cable
Battery
Back-Up
TOOLS REQUIRED
Sockets and Ratchet
Flat Screwdriver
Lag Bolts (shown full size)
Installation
Instructions
PARTS INCLUDED
7
/
16
"
1
/
4
"
Need help or have questions?
DO NOT RETURN to the store.