Speed Dome Camera Instruction Manual
37/50
Alarm Input Setup
ALARM INPUT SETUP
------------------------
ALARM NO. 1
TYPE N.OPEN
ACTION NOT USED
HOLD TIME ENDLESS
POST ACTION HOME
BACK
EXIT
Defines Alarm Function. When an alarm is received,
an input signal to the camera triggers the user-defined
action programmed for the alarm.
Alarm No
[1~3]
Selects a sensor number to set up.
Type
[Normally OPEN/Normally CLOSED]
Selects sensor operation type.
Action
[NOT
USED/PRESET/PATTERN/SWING/GROUP]
Selects an action to run when a sensor
signal is input.
Hold Time [ENDLESS / 1~59 SEC. / 1~180 MIN.]
Sets the time period for the action which is
run by external sensor activation. After the
time period passes, the action pre-defined
in
“
Post Action
”
runs sequentially in
succession to the action by external sensor
activation. If this option is set to
“
ENDLESS
”
,
“
Post Action
”
does not
activate.
Post Action [HOME/PRESET/PATTERN/SWING/GROUP
/PREV ACTION]
Selects the action that a camera will run
after the time period in
“
HOLD TIME
”
passes. If Post Action is set to
“
PREV.
ACTION
”
, the camera runs the most
recent previous action .
OSD MENU
4