SY-SIX-KLCS | Synergis IX Touch Sense LCD Keypad | Installation Manual
Last Updated July 2018
9
Connections
End of Line Termination (EOL)
The EOL (End of Line) jumper should be placed in the ON position when the keypad is inserted as the FIRST
or LAST module on the RS-485 network.
EOL
EOL Jumper OFF
EOL
EOL Jumper ON
Inputs
The keypad is capable of connecting to 4 inputs, where each input can then be programmed to perform the
required function in the Synergis System.
The following diagrams show examples of the input wiring configuration settings that can be programmed
under the Input options within the Synergis software.
Input (No Resistors):
Common
Input
1 (1+2)
Input
2 (3+4)
Input
2
N.C Input Contact
Input
1
N.C Input Contact
Z2
P1
Z1
NB
+
NA
-
Input (1K and 1K):
Input 1 (1+2)
Common
Input 2 (3+4)
N.C Tamper
N.C Tamper
Input 2
N.C Input Contact
Input 1
N.C Input Contact
1K
1K
1K
1K
Z2
P1
Z1
NB
+
NA
-