background image

 

 

SY-SIX-KLCS | Synergis IX Touch Sense LCD Keypad | Installation Manual 
Last Updated July 2018 

4

 

Introduction 

The Synergis IX Touch Sense LCD Keypad provides a sleek, user friendly human interface to the Synergis 
System, an advanced technology security product providing seamless and powerful integration of access, 
security and building automation. 

The current features of the keypad include: 

 

Securely login to the keypad with user codes from 1 to 8 digits with support for card reader and PIN code 
operation 

 

Intuitive menu function allows scrollable options according to user security level with quick access short 
cut keys for the power user 

 

Dual Code and Master Code provider functions for secure ATM and banking vault area access with 
automatic timeout and delayed opening functions 

 

Capacitive Touch Sense keypad 

 

Individual reportable duress code trouble for each keypad 

 

Activation of 3 Reportable Panic Events (Panic, Medical and Fire) 

 

Smoke detector reset provided on Clear and Enter keys selectable for an output or output group 

 

Available in white or black 

 

4 input (duplex mode) can be used to perform any system alarm and automation functions with a 
dedicated enclosure tamper switch 

 

1 low current output for driving any signalling device 

 

Содержание Synergis IX SY-SIX-KLCS

Страница 1: ...Synergis IX Touch Sense LCD Keypad SY SIX KLCS Installation Manual ...

Страница 2: ...f a product at the time of document s last revision and may not reflect the product at all times in the future In no event shall Genetec be liable to any person or entity with respect to any loss or damage that is incidental to or consequential upon the instructions found in this document or the computer software and hardware products described herein The use of this document is subject to the dis...

Страница 3: ...n 6 Keypad Version Information 7 Communication 8 Connections 9 End of Line Termination EOL 9 Inputs 9 Trouble Inputs 11 Outputs 12 LED Indicators 13 Error Messages 14 Keypad Version Error 14 Keypad Address Too High 14 Duplicate Keypad Address 14 Security Violation 14 Invalid Serial Number 14 Technical Specifications 15 New Zealand and Australia 16 European Standards 17 FCC Compliance Statements 19...

Страница 4: ...function allows scrollable options according to user security level with quick access short cut keys for the power user Dual Code and Master Code provider functions for secure ATM and banking vault area access with automatic timeout and delayed opening functions Capacitive Touch Sense keypad Individual reportable duress code trouble for each keypad Activation of 3 Reportable Panic Events Panic Med...

Страница 5: ...st Updated July 2018 5 Installation Requirements This equipment is to be installed in accordance with The product installation instructions The National Electrical Code ANSI NFPA 70 The Canadian Electrical Code Part I CSA C22 1 The Local Authority Having Jurisdiction AHJ ...

Страница 6: ...erational Keypad Address The address selection sets the address of the keypad This address must be a unique address in the Synergis System that is below an address of 250 Enter device address 256 Use the numerical keys 0 to 9 to program the address and press ENTER to save the setting To exit without making changes press the MENU key Backlight Brightness Setting The backlight brightness setting adj...

Страница 7: ...stallation Manual Last Updated July 2018 7 Keypad Version Information The version menu option displays the version and build information about the keypad The version information is displayed on two lines and can be scrolled Press the MENU key to exit ...

Страница 8: ...orates encrypted RS 485 communications technology for its module network Each system controller supports up to 250 keypads NA N N NB Next modules on network System Controller Module Network Communication Terminals Power Supply for Network Devices Powering modules on the system controller Keypad Terminal Connection AUX NA NB P1 Z1 Z2 ...

Страница 9: ...f connecting to 4 inputs where each input can then be programmed to perform the required function in the Synergis System The following diagrams show examples of the input wiring configuration settings that can be programmed under the Input options within the Synergis software Input No Resistors Common Input 1 1 2 Input 2 3 4 Input 2 N C Input Contact Input 1 N C Input Contact Z2 P1 Z1 NB NA Input ...

Страница 10: ... 2K4 Input 1 1 2 Common Input 2 3 4 N C Tamper N C Tamper Input 3 N C Input Contact Input 1 N C Input Contact Input 2 N C Input Contact 1K 1K 2K4 2K4 Z2 P1 Z1 NB NA Input 4 N C Input Contact To utilize the input duplex mode configuration shown above the input duplex setting must be enabled under the Input programming ...

Страница 11: ...X 01 Module Tamper Opens when the keypad is removed from the wall KPXXX 02 Reserved KPXXX 03 Keypad Panic Keys 1 and 3 are pressed together generating a panic message KPXXX 04 Keypad Duress A user code with the duress option enabled has entered a code on the keypad KPXXX 05 Reserved KPXXX 06 Reserved KPXXX 07 Too Many Codes Too many incorrect codes have been entered at the keypad and it has been l...

Страница 12: ...e 2 system status LED indicators system beeper and the open collector output The outputs can be activated and deactivated based on specific events or functions within the Synergis System PGM Function KPXXX 01 Open Collector Output on the Touch Sense Keypad terminal block P1 KPXXX 02 Armed Status Indicator LED Red KPXXX 03 Disarmed Status Indicator LED Green KPXXX 04 Beeper Output ...

Страница 13: ...s powered and operating normally If there is a complete power failure this indicator will be OFF Disarmed Indicator Indicates when the system is disarmed When ON the system is disarmed enter your user code to arm Armed Alarm Indicator When FLASHING the system is in alarm and you need to enter your user code to silence the alarm When ON the system is armed enter your user code to disarm Indication ...

Страница 14: ... address of the keypad that is programmed is beyond the maximum number of keypads that are allowed to connect to the controller You may also be able to adjust the controller profile to increase the keypad module capacity Press the EXIT key to restart the keypad Set the keypad address see page 6 to a lower value Duplicate Keypad Address The address of the keypad is already programmed into the syste...

Страница 15: ... all output functions 3 system status LEDs 1 system beeper Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 10 to 85 C 14 to 185 F Humidity 0 to 93 non condensing indoor use only relative humidity Dimensions 125 x 125 x 18mm 4 92 x 4 92 x 0 71 Weight 192g 6 77oz The size of conductor used for the supply of power to the unit should be adequate to prevent voltage drop at the terminals...

Страница 16: ...nse LCD Keypad Installation Manual Last Updated July 2018 16 New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards ...

Страница 17: ...event any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your national legislation For business users in the European Union If you wish to...

Страница 18: ...onds the entry delay has expired or another instant is violated the main alarm will be triggered and reported To comply with EN 50131 1 neither Internals Only on Part Set Zone Alarm nor Internals Only on Part Set Tamper Alarm should be selected To comply with EN 50131 1 Single Button Setting should not be selected To comply with EN 50131 1 only one battery can be connected and monitored per system...

Страница 19: ...h can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Changes or modifications not authorized by the p...

Страница 20: ...Keypad Installation Manual Last Updated July 2018 20 Industry Canada Statement This class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada CAN ICES 3 A NMB 3 A ...

Страница 21: ...c Logo are trademarks of Genetec Inc and may be registered or pending registration in several jurisdictions Other trademarks used in this document may be trademarks of the manufacturers or vendors of the respective products www genetec com Published July 2018 Submitted to UL 06 2018 ...

Отзывы: