GeneSys Elektronik GmbH
In der Spöck 10
77656 Offenburg
Germany +49 (0) 781 96 92 79
–
0 [email protected] www.genesys-offenburg.de
ADMA 3.5 Quick Start Guide.docx
Seite / Page 23 / 32
PARAMETER
Mounting offset angle
The offset values for the roll axis (X) and
the pitch axis (Y) can be determined
automatically using the set-up function
"Auto Roll / Pitch alignment". The
compensation value of the yaw axis (Z)
must be entered manually.
Mounting offset position
Specify the mounting offset as accurately
as possible. Recommended value:
•
for driving dynamics ±5 cm (X Y Z)
•
for position determination ±2 cm (X
Y) and ±5 cm (Z)
Virtual measurement point (POI1-8)
If the ADMA is not mounted in the Point Of
Interest (POI), it results in lever arms
between the ADMA and the installation
position. The lever arms can be
compensated by entering the XYZ offset
values.
Please note that large lever arms will
generate larger application noise.
ADD-ONS
The available ADD-ONS depend on your
purchased license.