51
ReACT Pro
MANAGING DECOMPRESSION STOPS
The amount of decompression Credit Time that you receive is dependent on Depth, with slightly
less Credit given the deeper you are below a Required Stop Depth.
You should stay slightly deeper (Fig. 55a) than the Required Stop Depth indicated (Fig. 55b) un-
til the next shallower Stop Depth appears. Then, you can slowly ascend to, but not shallower
than that indicated ceiling Stop Depth.
WARNING: You must not ascend shallower than the decompression
ceiling indicated. Doing so will greatly increase your risk of
decompression sickness and place the ReACT Pro into a Conditional
Violation Mode (described on the next page).
Once all required decompression has been completed, the ReACT Pro will revert to the No De-
compression Dive Mode (Fig. 56). This is indicated by Total Ascent Time = 0:00, and the Ni-
trogen Bar Graph receding into the Caution Zone.
Dive Time Remaining now appears in place of Total Ascent Time displaying the No Decom-
pression Time Remaining (NDL) or Oxygen Accumulation Time Remaining (OTL), whichever
time is the least and in control.
Fig. 55 - Managing a Deco
Stop
Fig. 56 - Deco Completed
TAT
TAT
FT
FT
STOP
STOP
NITROX
E
D
O
D
E
C
a
b
FT
FT
NITROX
E
D
Содержание React Pro
Страница 1: ...OWNER S MANUAL OWNER S MANUAL React Pro...
Страница 11: ...11 ReACT Pro FEATURES and DISPLAYS...
Страница 21: ...21 ReACT Pro ACTIVATION and SETUP...
Страница 31: ...31 ReACT Pro PRE DIVE and DIVE MODES...
Страница 39: ...39 ReACT Pro POST DIVE MODES...
Страница 47: ...47 ReACT Pro SPECIAL SITUATIONS...
Страница 63: ...63 ReACT Pro CARE INSPECTION AND SERVICE...
Страница 73: ...73 ReACT Pro REFERENCE...