background image

Programming: Display and Instructions 

Programming Instructions

Manual / Delayed Regeneration 

Pressing 

at any time results in an immediate manual regeneration. 

Pressing and holding 

for 3 seconds, when system is locked, results in a delayed regeneration at the preselected time. 

One Button to Change the Current Time 

Pressing and holding the 

button for 3 seconds, when system is locked, allows the current time of day to be adjusted. 

Unlocking the Keypad

    icon indicates the buttons are locked within 5 minutes of idle use. To unlock press and hold 

and 

for 3 seconds 

until the      icon is off. 

Enter Key 

Press 

button to enter the basic programming mode, modify highlighted options, and return to the main menu. 

Manual Regen/Esc. Key

Press 

at any phase during manual regeneration to advance to the next phase or press during programming to exit 

to the home screen without modifying the current highlighted option. 

Up and Down Arrows

or 

buttons are used to scroll through the various basic programming options as well as adjust values. 

Programming Modes

Basic Programming – Allows you to adjust the time values for each phase. To enter basic programming, follow the

directions below. 

When the      icon is on, press and hold both 

and

for 3 seconds to unlock the keypad; then press 

to enter the 

main menu; press 

or      to highlight each option. Press 

to enter that option. Press 

or 

to adjust the value. 

Press 

to accept changes. (Press 

to exit back to service status

)

9

Содержание GEN2AI015

Страница 1: ...GENESIS 2 OZONE FILTRATION SYSTEM SERVICE MANUAL J J z l 1 w z s REVISION 1 REVISION DATE 9 17 2020 support www discount watersofteners com...

Страница 2: ...lication Check List and Flushing Instructions 2 System Specifications 3 Product Features and Applications 4 Product Dimensions and Specification 5 Pre installation Checklist 6 Installation 7 8 Program...

Страница 3: ...n and suspended solids 7 The start up backwash and rinse prior to new service installation is critical for cleaning media of manufacturing color taste and any trace amine odors We recommend 2 bed volu...

Страница 4: ...tions GEN2AIO25 GEN2AIO30 72 2 74 150 90 72 1 91 200 120 14 16 15 20 3 4 20 120 PSI 1 to 5 PPM Ferrous Control Valve Working Conditions Transformer Input Transformer Output Water Pressure Water Tempur...

Страница 5: ...ously for 3 seconds to unlock LCD Display Screen Maximum Day Regeneration Interval When the valve reaches the maximum programmed service days without reaching the set service capacity it will trigger...

Страница 6: ...reaches zero A 03 Intelligent Meter Delay The same delay function as A 01 but the capacity is determined by entering the total Resin Capacity Feed Water Hardness and the Number of People in the househ...

Страница 7: ...m Any modifications the Discount Water Softeners equipment which is outside the standard scope of supply voids the product warranty Discount Water Softeners equipment like all modern electronic device...

Страница 8: ...ipment installed in inappropriate applications or environment are not covered by warranty Plumbing and Mechanical Setup Note 1 If making a soldered copper installation all sweat soldering should be do...

Страница 9: ...Installation Continued Ceramic Bypasses Part Number 41205 Ceramic Bypass 8...

Страница 10: ...e basic programming mode modify highlighted options and return to the main menu Manual Regen Esc Key Press at any phase during manual regeneration to advance to the next phase or press during programm...