55
Englis
h
IMPORTANT FOR REMOTE CONTROL USE:
When the generator is off and the remote receiver active (waiting for the start
signal) there is a power consumption. This small consumption is supplied by the
generator battery.
If the generator is 12 hours without activity (without start) the remote receiver
generator is disconnected automatically to preventing battery discharge. To
reactivate the remote control function it is necessary to reactivate the remote
receiver pressing "
RESTART RECEIVER
" on the control panel
6 Carburetor alteration for high altitude operation
In high altitudes, the normal air-fuel blend in the carburetor would be too rich.
Performance would decrease and fuel consumption would increase. A very rich
blend would also dirty the spark plug and make startup difficult.
If the generator is always running in an altitude above 900 meters, get in touch
with an authorized service to modify the carburetor (this service is not warranty,
therefore it would be quoted).
The generator's output power of 230V will vary depending on the altitude and
other elements such as humidity and temperature, se chapter on environmental
correction of this manual.
NOTE:
If the carburetor has been
modified to operate at great altitude, the
air-fuel blend would be too poor to work
in low altitudes. Operation at low
altitudes may cause the engine to
overheat and be seriously damaged. It
would be necessary to return the
carburetor to its original state.
Reference
Description
401049
Injector 900-1800mts
401050
Injector 1800-2500mts
401051
Fuel cup seal
Note: The fuel cup seal maybe damaged
during removal, we suggest replace
together main jet.
Carburetor
Fuel cap seal
Main jet
Fuel cup
Bolt